Gas supply
line
1/2" I,D, pipe is recommended,
3/s" approved
tubing is acceptable
for lengths under 20 ft (6,1 m) if
local codes and gas supptier
permit,
Must include 1/s" NPT plugged
tapping,
immediately
upstream
of
the gas connection,
A shut off vatve must be included:
USA:
An individual
manual shut off
valve must be installed within
6ft (1.8 m) of the dryer in
accordance
with the National
Fuel Gas Code, ANSI Z223,1,
Canada:
An individual
manual shut off
valve must be installed in
accordance
with the B149,
Installation Codes, CAN/CSA
B149,1 and CAN/CSA
B149,2,
It is recommended
that an
individual
manual shut off valve
be instatled within 6 ff (1,8 m) of
the dryer,
1
-
1/2"
NPTgassupplyline
2-
Gasshut-0ff valve
3-
1/8" NPTpluggedtapping
4-
3/8" pipeto flareadapterfitting
5-
3/s" flexiblegasconnector(tothe dryer)
The shut off valve should be easy to
reach for opening and closing,
Dryer gas pipe
The gas pipe that comes out
through the rear of the dryer has
a 3/8" male pipe thread,
Connection
of the dryer
Connection
must be made by
a qualified
technician,
The dryer must be disconnected
from the gas supply piping
system during testing pressure,
When using for the first time
make sure that there is no air in
the piping system,
Do not use copper
pipes and
tubing if connected
to natural
gas,
The connection
may be different,
according
to the supply line type,
size and location,
If local codes permit, use a flexible
stainless steel connector
(Design
certified by the America Gas
Association
or CSA International)
to connect
the dryer,
1
2
1 -
gaspipe (3/8"malepipethread)
2-
3/8" elbow
To reduce the distance
between
body sheet and wall install
a 3/8" elbow on the gas pipe of the
dryer,
Exhaust air connection
1. To reduce the risk of fire, this
dryer MUST BE EXHAUSTED
OUTDOORS,
2. To reduce the risk of fire, do
not use ductwork
longer than
recommended,
3. DO NOT use a plastic or
non-metal
duct with this dryer,
4. DO NOT use a duct smaller
than 4 inches in diameter,
5. DO NOT use exhaust hoods
with magnetic
latches,
6. DO NOT exhaust the dryer into
a chimney, furnace cold air
duct, attic, crawl space, or any
other ductwork
used for
venting,
7. DO NOT install a flexible duct
in an enclosed
watt, ceiling or
floor,
8. DO NOT crush or kink the
duct,
9. Do clean and inspect the
exhaust
system on a regular
basis; at least once a year,
10. The exhaust duct must
terminate
in a manner to
prevent back drafts or entry of
birds or other wildlife,
The Bosch dryers must be vented
outdoors,
To prevent build up of
moisture
and accumulation
of tint
indoors, as well as to maintain
maximum
drying efficiency,
it is
recommended
that the dryer is
vented outdoors,
Exhaust
air outlet
on the dryer
The dryer is delivered with an
exhaust air outlet on the rear of the
appliance,
To take account
of the spatial
requirements
and an existing
exhaust air system, the following
connection
options are possible for
the exhaust
air outlet:
on right side of the appliance,
on the underside
of the
appliance,

Hide quick links: