DO NOT assemble
the ductwork
with screws or fasteners that
extend into the duct, They witl serve
as an accumulation
point for tint,
Joints should be secured with duct
tape,
More than two 90 ° turns are not
recommended.
For best
performance,
separate atl turns by
at least 4 ft. of straight duct,
including
distance
between
last turn
and exhaust
hood.
1 -
Exhaust a ir outleton the rear of the
appliance(standard)
2-
Exhaust a ir outleton the side(optional)
3 -
Exhaust a ir outleton the underside of the
appliance(optional)
Speciat exhaust air connections
must be obtained
from our
customer
service for either
connection
type (see page 11).
Side air exhaust
Bottom air exhaust
A qualified technician
should
change the exhaust air outlet to the
optional
connection
location.
Ductwork
To ensure optimum
performance,
the ducting system of the dryer
should be as short as possible with
a minimum
number of elbows.
Your dryer will work best when the
venting system has as few air flow
restrictions
as possible.
Exhaust
ducting which is longer than
recommended
may extend drying
time, cause tint to accumulate
and
affect dryer performance
and dryer
life.
Four inch (approx.
100 mm)
diameter
ducting should be used.
Use either rigid metal or flexible
metal ducting material.
DO NOT
use plastic or non metal duct with
this dryer.
/
All joints should be tight to avoid
leaks. The mate end of each duct
section must point away from the
dryer.
Whether connecting
to an existing
venting system or a new venting
system, make sure that atI ducting
is clean and free of tint.
The maximum
permitted
length for
both rigid and flexible metal duct is
shown in the table betow.
Numberof
RigidDuct
FlexibbDuct
90°Turns
or Elbows
0
66 ft.
45 ft,
(2011 cm)
(1372cm)
1
56 ft.
36 ft,
(1707 cm)
(1097cm)
2
48 ft,
29 ft,
(1463 cm)
(884cm)
3
39 ft,
22 ft.
(1189 cm)
(671cm)
4
30ft,
16ft,
(914 cm)
(488cm)
Note:
Side and bottom
exhaust
installations
have a 90 ° turn inside
the dryer. To determine
maximum
exhaust length, add one 90 ° turn to
the chart.
Good
Better
Exhaust
vent hood
The exhaust
duct must end with an
approved
exhaust vent hood with
swing out damper(s).
DO NOT use
an exhaust vent hood with
magnetic
tatches.
To avoid exhaust restriction,
the
outlet must be a minimum
of
12 inches (30 cm) above ground
tevet or any other obstructing
surface.
...............
Required
parts
The parts required for the exhaust
air system (etbows, tines, exhaust
air outIets) are not included
in
standard
delivery of the dryer.