Testing Call Router
To test Call Router:
1.
With Call Router function stopped, go to Test in the Tool drop-down
list of the Call Router main menu for the Test dialog box.
2.
In the Configuration fields, you can input the following test
parameters:
• Number of concurrent calls
• Interval between calls
• Number of test cycles
For example, inputting 5 for concurrent calls, 3 for interval between
calls, and 4 for test cycles means that every 3 seconds, there will be 5
concurrent call requests to Call Router. Total cycles of concurrent
requests will be 4 times.
3.
After inputting the test parameters, click Start. During the test, you
can click Stop to stop the test. The title of the Test dialog box will be
shown as "Test(Started)" while running.