R. Troubleshootings
Symptom
Fan are not operatable.
Illuminating LED light
does not work
Hood vibrates.
S. Replace The LED Light
Before changing LED light ensure the unit is pressed the
when you want to change the LED light please always wear working gloves.
1. Using suitable tool (small slotted screw driver) gently pry off the LED light set.
2. Taking off the wire connecter with LED light set.
3. Replace a new LED light set and reconnect the wire to the connector.
4. Before push back the original LED light position, test the LED light.
LED driver:
Model: HP1500-36
input: 100~240vdc
output: 3.6vdc=1500maH
NOTE: For LED light replacement, you may not find the appropriate LED lights
from market, please contact with distributor(s)/dealer(s).
Correction
A. Check power source to see if it is normal.
B. Check power inlet plug to see if it is
plugged firmly into it's socket.
A. Disconnect the power source.
B. Check LED light, replace it with a new
one if it is burned out.
A. Check for damaged vanes.
B. Check if exhaust duct is secured.
19
main power button off,
LED light: 1W
Model: HP-15A

Advertisement