Electrical Data - Vulcan-Hart CB1824E Installation & Operation Manual

Conveyorized pizza oven
Table of Contents

Advertisement

Cord Connected Ovens
WARNING: THE ELECTRICAL CORD HAS A GROUNDING PLUG WHICH MUST BE CONNECTED
TO A PROPERLY GROUNDED RECEPTACLE. IF THE RECEPTACLE IS NOT THE PROPER
GROUNDING TYPE, CONTACT AN ELECTRICIAN. DO NOT REMOVE THE GROUNDING PRONG
FROM THE PLUG.
Volts / Hz
Model
/ Ph
CB1824E
208/60/1
CB1824E
240/60/1
CB1824E
208/60/3
CB1824E
240/60/3
Circuit Size (Minimum) & Fuse / Circuit Breaker Size (Maximum) compiled in accordance with the National Electrical Code (ANSI/
NFPA 70), 1993 Edition.

ELECTRICAL DATA

Kilowatts
9.4
9.4
Per Phase
L1 - L2
L2 - L3
L1 - L3
5.2
1.6
2.6
5.2
1.6
2.6
Rated Amps
45.2
39.2
Per Line Wire
L1
L2
32.5
28.3
17.5
28.2
24.5
15.2
— 4 —
Fuse
Size or
Circuit
Circuit
Size
Breaker
(Amps)
Size*
(Amps)
60
60
50
50
L3
40
40
40
40
* Dual Element Time-Delay Fuse or
Inverse Time Circuit Breaker
90°
Copper
Wire Size
6
8
8
8