There must be a 3" (76 mm) clearance on each side of the oven. There must be a 3" (76 mm) clearance
to the rear of the oven as well. The area behind the oven around the blower must be kept clear of
obstructions and allow for free air circulation.
Ensure that the cord can be plugged into the appropriate outlet.

INSTALLATION CODES AND STANDARDS

The VFB2 Flash Bake oven must be installed in accordance with:
In the United States of America:
1. State and local codes.
2. National Electrical Code, ANSI/NFPA-70 (latest edition). Copies may be obtained from The
National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

ELECTRICAL CONNECTIONS

The VFB2 Flash Bake oven has a 5 foot (1524 mm) power cord for receptacle installation.
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE
APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL
ELECTRICAL CODES.
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT
SWITCH TO INDICATE YOU ARE WORKING ON THE CIRCUIT.
1
2
0
1
6
0
V
o
l
a t
g
e
P
h
a
s
e
C
y
c
e l
s
WARNING: APPLIANCES EQUIPPED WITH A FLEXIBLE ELECTRIC SUPPLY CORD ARE PROVIDED
WITH A THREE-PRONG GROUNDING PLUG. IT IS IMPERATIVE THAT THIS PLUG BE
CONNECTED INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE. IF THE
RECEPTACLE IS NOT THE PROPER GROUNDING TYPE, CONTACT AN ELECTRICIAN. DO NOT
REMOVE THE GROUNDING PRONG FROM THIS PLUG.
CORD-CONNECTED OVENS
Plug the oven into a dedicated circuit outlet of the appropriate NEMA style and rating.
RECEPTACLE
15 Amp
NEMA 5-15R
Fig. 1
The outlet must be properly wired with the correct polarity and grounding or the oven will not operate
properly.
PL-53370
ELECTRICAL DATA
– 5 –