Features; Controls And Indicators; Equalizing - Black & Decker VEC1089ABD User Manual

Fully automatic electronic smart battery charger 15 amp / 10 amp / 2 amp charge rates
Table of Contents

Advertisement

VEC1089ABD_Manual_042805
5/9/05
internal chemical energy transfer. At the end of Stage 2, the charger will automatically
move into Stage 3 charge mode.
Stage Three — Top-Off Charge — voltage is automatically maintained and
reduced to a predetermined level while current is adjusted for a safe, effective battery
charge. At the conclusion of Stage 3, the unit will BEEP signaling the completion of
the charging cycle.
The Automatic Float Charge feature is ideal for maintaining a battery. It automatically
tops off battery as needed, to keep battery fully charged all the time.

FEATURES

• This unit has three charge rate settings, accessed by the 2/10/15 AMP button:
a) 2 amps: smaller batteries, as in lawn mowers, snowmobiles, motorcycles, etc.
b) 10 amps: mid-sized batteries, as in small cars
c) 15 amps: automobiles and light trucks
• Automatic Temperature Compensation
• Battery type selection
• Digital diagnostics
• Alternator voltage and battery voltage check
• Digital display
• 3
-minute engine start
1
2
• 3-stage, high-frequency switch mode automatic rapid charging
• Spark resistant reverse polarity and short circuit protection for user
• Lightweight, high efficiency design
• Cables and clamps self-stored
• Microprocessor control (Digital Smart Control)/High frequency power
• Compensates for low AC from extension cord use
• Equalization function
• Battery recondition function

Controls and Indicators

CONTROL PANEL
FUNCTION BUTTONS (FROM RIGHT TO LEFT):
Battery Type — allows the user to select wet battery, gel battery or AGM battery.
2/10/15 Charge Rate Selector — allows the user to select the charge rate
based on battery size. This selection and actual battery charge rate are monitored by
the microprocessor and will stop charging if the rate is too fast or too slow for battery
size or condition.
2:40 PM
Page 2
DIGITAL READOUT
CIRCULATING PATTERN
2
Battery Voltage — enables a check that measures the battery voltage and displays
it for 3 seconds.
Battery Recond — improves performance of sulfated and aged batteries.
Alternator Check — is a five-second check that measures the battery voltage. This
check is repeated at various electrical load levels and the tests allow the user to
determine if the alternator can keep up with the loads. It can indicate alternator
voltage is out of typical operation voltage.
INDICATORS:
Large (.375") 3-Character Digital Display in the upper left of the control panel
indicates the various conditions and/or status codes:
Status Codes are described in the following chart and on back of the charger.
AC POWER INDICATOR - When connected to an AC outlet, digital display shows circulating pattern to indicate power
is on. Disconnect charger after use.
FAULT CODES
F01
INTERNAL SHORTED CELL BATTERY - Cannot be charged. Have battery checked by certified auto service center.
EXCESSIVE LOAD ON BATTERY WHILE CHARGING - Check load.
F02
BAD BATTERY CONNECTION - Check battery connection.
BATTERY VOLTAGE TOO LOW TO ACCEPT CHARGE - Have battery checked by certified auto service center.
F03
INTERNAL OPEN CELL - Have battery checked by certified auto service center.
SULFATED CONDITION - Battery needs to be reconditioned. See manual.
OVERTIME CONDITION - Battery will not accept a charge after 18 hours of continuous charging. Battery may have
F04
internal damage. Have battery checked by certified auto service center.
BATTERY CHARGE RATE IS SET TOO LOW - Set charger to higher charge rate. See manual.
CONTROL PANEL LED INDICATORS:
WET — lights when battery type selector is on WET battery type
GEL — lights when battery type selector is on GEL battery type
AGM — lights when battery type selector is on AGM battery type
Float Charge — lights when automatic charge monitoring is active
Alternator Good — lights when load or no load checks show the alternator is
keeping up with the electrical load
BUTTON (BELOW THE DIGITAL DISPLAY):
Equalizing — a recessed button used to start the equalization process.
F05
OVERHEATED CONDITION - Disconnect charger and allow to cool for 30 min., check for ample ventilation.
F06
REVERSE POLARITY
F07
ALTERNATOR OUTPUT IS OUT OF TYPICAL OPERATION RANGE
OPERATION CODES
BATTERY RECONDITIONING - (The letters DES will display for the first 3 seconds.)
ALTERNATOR VOLTAGE CHECK
000
CHARGER STANDBY
FUL
BATTERY FULLY CHARGED
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents