Removal/Replacement

This section describes the removal and replacement procedures for the following field replaceable units
(FRU):
SFP and XPAK transceivers
Power supplies for the SN6000 Single Supply Switch and the SN6000 Dual Power Supply Fibre
Channel Switch models
The switch is equipped with a battery that powers the non-volatile memory. This memory stores the
switch configuration. The battery is not a field replaceable unit.
WARNING!
type recommended by the manufacturer. Dispose of the used battery according to the manufacturer's
instructions.
WARNING!
gleichen Batterie oder mit einem äquivalenten, vom Hersteller empfohlenen Batterietyp ersetzen. Die
gebrauchte Batterie gemäß den Herstelleranweisungen entsorgen.
WARNING!
pile de type identique ou équivalent recommandé par le fabricant. Jeter la pile usagée en observant les
instructions du fabricant.
WARNING!
con el mismo tipo o equivalente recomendado por el fabricante. Deshágase de la batería usada según las
instrucciones del fabricante.

Transceiver removal and replacement

The SFP and XPAK transceivers can be removed and replaced while the switch is operating without
damaging the switch or the transceiver. However, data transmission on the affected port is interrupted until
the transceiver is installed.
To remove a transceiver, gently press the transceiver into the port to release the tension, then pull on the
release tab or lever and remove the transceiver. Different transceiver manufacturers have different release
mechanisms. Consult the documentation for your transceiver. To install the transceiver, insert it into the port
and gently press until it snaps in place.
NOTE:
The SFP and XPAK transceivers fits only one way. If the transceiver does not install under gentle
pressure, invert it and try again.

Power supply removal and replacement

The SN6000 Dual Power Supply Fibre Channel Switch power supplies are hot-pluggable. This means you
can remove or install one of the power supplies while the switch is operating without disrupting service.
The power supplies are also interchangeable; that is, the left and right power supplies are the same unit.
The battery may explode if replaced incorrectly. Replace only with the same or equivalent
Bei unsachgemäß ausgetauschter Batterie besteht Explosionsgefahr. Die Batterie nur mit der
Danger d'explosion si le remplacement de la pile est incorrect. Ne remplacer que par une
Peligro de la explosión si la batería es reemplazada incorrectamente. Substituya solamente
HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide
61