Switch LEDs and controls

The switch LEDs provide information about the switch's operational status. These LEDS include the Input
Power LED (green), Heartbeat LED (green), and the System Fault LED (amber)
about port LEDs, see
is used to reset a switch or to recover a disabled switch. To apply power to the switch, plug the power cord
into the switch AC power receptacle, located on the back of the switch, and into a 100–240 VAC power
source. The power supply (or supplies) must be plugged in order for the switch to be powered on. Refer to
"Power supplies and
2
1

Input Power LED (green)

3

System Fault LED (amber)

Figure 2

Switch LEDs and controls

Input power LED (green)
The Input Power LED indicates the voltage status at the switch logic circuitry. During normal operation, this
LED illuminates to indicate that the switch logic circuitry is receiving the proper DC voltages. When the
switch is in maintenance mode, this LED is extinguished.

Heartbeat LED (green)

The Heartbeat LED indicates the status of the internal switch processor and the results of the POST.
Following a normal power-up, the Heartbeat LED blinks about once per second to indicate that the switch
passed the POST and that the internal switch processor is running. In maintenance mode, the Heartbeat
LED illuminates continuously. For more information, see
System fault LED (amber)
The System Fault LED illuminates to indicate that a fault exists in the switch firmware or hardware. Fault
conditions include POST errors, over-temperature conditions, and power supply malfunctions. The
Heartbeat LED shows a blink code for POST errors and over-temperature conditions. For more information,
see
"Heartbeat LED blink
10
"Port
LEDs" (page 13). The Maintenance button
fans" (page 16) for more information on power supplies.
1
3
4
patterns" (page 52).
(Figure
2) is the only switch control. It
2
Heartbeat LED (green)
4
Maintenance button
"Heartbeat LED blink
(Figure
2). For information
patterns" (page 52).