Data Exchange Code Converter Error Codes And Basic Troubleshooting Guidelines - HP StorageWorks P9000 User Manual

Data exchange code converter user guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Error Code
CCNV10Y-I
CCNV10Z-I
CCNV110-I
CCNV111-I
CCNV113-I
CCNV114-I
CCNV115-I
CCNV116-I
Data Exchange Code Converter Error Codes and Basic Troubleshooting
Guidelines
Table 21
contains the Data Exchange Code Converter error codes and an explanation and
recommended action for each of them. When an error occurs and the cause cannot be identified,
gather the following information and contact your HP service representative.
UNIX Systems:
84
Troubleshooting
Error Message and Description
Cannot make changes to the standard
code conversion table. The standard code
conversion table provided cannot be
changed.
Version of the code conversion table is
wrong.
Code conversion table is wrong.
Code conversion table is corrupted, or a
file other than a code conversion table is
specified.
Code conversion table to customize is not
specified.
Tried to output code conversion table
information or code conversion table dump
with option -I(-i) or -P(-p), but the code
conversion table is not specified.
Encountered an unexpected error.
Could not obtain necessary information
during utility execution due to reasons such
as memory corruption.
The range of codes before and after the
conversion does not match.
Tried to customize a table that converts into
EUC code, but the converted code does
not correspond to the EUC code range.
Converted code (code) does not exist in
the code conversion table.
Converted code does not exist in the code
conversion table. This statement is ignored.
The value specified for the converted code
(code) is not right.
Action(s)
System action: Terminates operation
(Termination code 12).
User action: Create a new table when
customizing the standard code conversion
table.
System action: Terminates operation
(Termination code 12).
User action: Check the code conversion
table, and then re-execute.
System action: Terminates operation
(Termination code 12).
User action: Use a valid code conversion
table. If the table is corrupted for any
reason, re-execute after regenerating the
standard code conversion table.
System action: Terminates operation
(Termination code 12).
User action: Specify the code conversion
table with the -T(-t) option after option -I(-i)
or -P(-p).
System action: Terminates operation
(Termination code 12).
User action: Check the system environment,
and then re-execute.
System action: Terminates operation
(Termination code 12).
User action: Correct code range to match
EUC code set 1 or 3, and then re-execute.
System action: Proceeds to the next
definition statement (Termination code 08).
User action: Check the converted code,
and then re-execute.
A coding scheme where the converted
code is a double-byte code was specified
a value larger than 2 bytes.

Advertisement

Table of Contents
loading