Error Code
Error message
"Field definition file : Top
-650
point error"
"Field definition file : Field
-651
size error"
"Field definition file : Item
-652
count error"
"Field definition file : Edit
-653
kind error"
-655
"Memory allocate error"
"Field definition file :
-656
Character is not #/fld/end
error".
-657
"Memory allocate error"
-659
"Memory allocate error"
"Edit option file : Invalid
-660
format error"
"Edit option file :
-661
Information over flow"
"Edit option file : Invalid
-662
format error"
"Edit option file :
-663
Information count error"
Meaning
Byte position of the Field
Definition file parameter is
wrong.
Field length of the Field
Definition file parameter is
wrong.
The number of the Field
Definition file parameter is
less than required.
Field attribute of Field
Definition file parameter is
wrong.
Cannot allocate memory for
reading field information.
A value other than fld, end,
or # is specified in the Field
Definition file.
Cannot allocate memory for
reading the Field Definition
file.
Cannot allocate memory for
reading the Edit Option file.
Conversion mode or end
indicator of the Edit Option
file is wrong.
The Edit Option file
contains too much
information or does not
contain a []".
Conversion mode of the
Edit Option file is wrong.
Number of the Edit Option
file parameter is insufficient.
P9000 Data Exchange Code Converter User Guide
Action
Check the Field Definition
file.
Check the Field Definition
file.
Check the Field Definition
file.
Check the Field Definition
file.
Select Error from the Help
menu to view the system
error code, and then check
the operating system
document for error details.
Check the Field Definition
file
Select Error from the Help
menu to view the system
error code, and then check
the operating system
document for error details.
Select Error from the Help
menu to view the system
error code, and then check
the operating system
document for error details.
Check the Edit Option file.
(conversion mode need to
close by ]")
Check the Edit Option file.
Check the Edit Option file.
Check the Edit Option file.