Managing the HP NetStorage 6000 Using Telnet
Configuring E-mail
This menu configures the Telnet ability to send e-mail to specific recipients when there is a problem with the
RAID subsystem or the UPS module. The following appears:
To configure the RAID/UPS e-mail:
1. From the Telnet main menu press the space bar then select U. E-mail Configuration.
2. From the E-mail Configuration screen, select 1. Edit fields.
3. Type the information requested by each field. Press Enter to move between fields.
• SMTP Server Name
• Recipient 1...4
• Notification Level
• RAID Subject Field
• UPS Subject Field
4. Select 7. Save Changes to save the current configuration. Select 0. Cancel to abort this operation.
E-mail configuration is complete.
5. Press Esc to return to the main menu.
34
This is the mail server; all mail is directed here. The server name must be
present in the host file or the DOS server.
These are the e-mail addresses of the four people automatically notified in
case of a RAID or UPS problem.
The level a problem must be at before the recipients are notified via e-mail.
1) None: No notifications sent.
2) errors: Notifications sent only for errors.
3) errors_warnings: Notifications sent for errors and low priority
warnings.
The topic displayed in the subject field of any e-mail notification dealing
with RAID problems; useful in multiple server environments.
The topic displayed in the subject field of any e-mail notification dealing
with UPS problems useful in multiple server environments.