FIREPLACE SPECIFICATIONS - SSDVPF (PENINSULA VIEW)
SPECIFICATIONS
Natural & Propane
(MV Low 30,000)
Gas BTU Input
4-1/2" Inner
Co-axial DV Vent Size
7-1/2" Outer
NOTES
Annual Fuel Utilization Efficiency
Diagrams, illustrations and photographs are
not to scale – consult installation instruc-
tions. Product designs, materials, dimen-
sions, specifications, colors and prices are
subject to change or discontinuance without
notice.
Appliance has a factory-installed vent seal cap
(see Figures 15 and 16 on Page 13) in each
flue outlet.
PRODUCT REFERENCE INFORMATION
Cat.
Model
Ship
No.
Wt.
H3335
SSDVPF-CNM
270 lbs
H3336
SSDVPF-CNE
270 lbs
EFFICIENCIES
SSDVPF
58 % (NG)
61 % (LP)
72 % (NG)
Steady State
73 % (LP)
68 % (NG)
• AFUE
68 % (LP)
24
(610)
18-1/4
(464)
Left Side View
Figure 13
• Inches (millimeters)
• Minimum Framing Stud Size is 2 x 4
• See right side viewsof fireplace below for gas line inlet location options.
37,500
Vent Center - Top
Vent with one 90
degree elbow
12-1/8
(308)
5-1/8
(130)
Vent Center- Side
Vent (no elbows)
12-1/8
(308)
Ship.
Volume
52W x 27D x
44-1/2H (36.2
cu.ft).
* This dimension can be reduced to 41 inches (1041 mm). This results in 0 in. (0 mm) clearance between framing and unit framing
spacers. (The 41-1/2 in. dimension permits easier fireplace installation, if unit is installed after framing is erected).
52W x 27D x
** This dimension based on 5/8" drywall. For 1/2" drywall use 25-1/2" (648 mm). The finished dimension should be 26-1/2" (673 mm).
44-1/2H (36.2
See also, Side Vent Seal Cap note below.
cu.ft).
Vertical Venting Through the Ceiling:
Frame ceiling opening - Use a plumb line from the ceiling above the appliance to locate center of the vertical run. Cut and/or frame an opening,
10-1/2" x 10-1/2" (267 mm x 267 mm) inside dimensions, about this center mark (see Figure 19 on Page 15).
FINISH WALL BRACKET
(Front, back, and left edge of unit top)
41
(1041)
24
(610)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Fireplace Framing Specifications
**25-1/4
(641)
Dimension A
Secure Vent 47-1/8 (1194)
Secure Flex 47-7/8 (1216)
10-1/2
(267)
5-1/8
A
(130)
Center of gas line
is 3 in. (76 mm)
up from floor.
26-3/4
(648)
Secure Vent - 46-1/2 (1181)
Secure Flex - 48-1/4 (1226)
Gas Line Center of gas line is 3 in. (76 mm) up from floor.
10
(254)
FLUE
(Top or Side)
40-1/8
(1019)
Top View
43-5/8
(1108)
1/2
(13)
34-3/8
(873)
2-1/2
24
(63.5)
(610)
Louvered Control
Front View
Compartment Door
inches (millimeters)
11-3/8
10-1/2
(267)
7
(178)
12-1/8
(308)
7
(178)
5-1/8
(130)
12-1/8
(308)
A
5-1/8
26-3/4
(130)
(679)
Gas Line
Dimension A
43-5/8
(1108)
Stepped to Accept Drywall on 2 Corners
FRAMING SPACERS
(Top and Side)
12 (305)
FINISH WALL BRACKET
5/8
(16)
3-1/2 (89)
2-1/2
(63.5)
4 (102)
37
(940)
Provide
additional
space for Side
Vent Seal Cap
if installing
against a solid
wall.
3 (76)
6-7/8
(175)
Minimum Framing
Stud Size is 2 x 4
Vent Framing - Top Vent
With One 90º Elbow
Vent Framing - Rear Vent
With No Elbows
6-1/4
*41-1/2
(159)
(1054)
22-3/4
(578)
DETAIL OF
1/2
(13)
12
(305)
10-1/4
(260)
FLUE
(Top or Side)
ELECTRICAL
INLETS
GAS INLET
Right Side View
11