Troubleshooting - GE 3020511 Installation Manual

Brine valve

Advertisement

Troubleshooting

Problem
No water refill into the
salt tank
Excessive refill
System uses less brine
than the regnerate
setting
Possible Cause
Brine valve not operating
Obstruction in regenerant tube or valve
Damaged brine valve
Seal leak or failure
The float does not close off incoming water
Damaged brine valve
Air leak
Regenerant tube is too long
Brine valve is set incorrectly
The check ball was pulled at wrong time
Check that the brine valve is vertical and
moving freely.
Water flow is greater than 1.2 gpm
(4.5 L/m). Replace the refill control
washer with a smaller inside diameter
washer.
Check to see if there is too much air in
the resin tank.
Inspect pipline, remove any debris.
Replace brine valve.
Check for debris on seal.
Replace the seal.
Float is restricted by the bracket. Raise
top bracket to allow more space for float
movement.
Replace brine valve.
Inspect pipeline and repair leaks.
Be sure the length is less than 6.6 ft (2 m).
Check and adjust floater to appropriate
height.
Be sure the refill controller is an
appropriate size.
Remove the check ball enclosure.
3
Brine Valve PN 3020511