CHAPTER 2: S5U1C63000H2 PACKAGE

2.5 Setting the Dip Switch

The S5U1C63000H2 works with a personal computer that runs Windows as a host. With a general
computer that meets the condition, the serial transfer rate set at the factory (9600 bps) is good for use. In
case the rate is changed, the transfer rate between the host computer can be changed by this switch. The
switch also sets a self diagnostic function, which is equipped in the S5U1C63000H2, working or not
working at the power on. Figure 2.5.1 shows the dip switch.
<Setting baud rate>
SW1–3
SW4
SW5
OPEN
OPEN
OPEN
OPEN
OPEN
ON
OPEN
ON
OPEN
OPEN
OPEN
OPEN
OPEN
ON
ON
Other settings
Note: The setting at the host end is recommended to be "9600 bps, 8-bit character, 1 stop bit, no parity".
<Setting the self diagnostic function>
SW8
OPEN
Self diagnosis On
ON
Self diagnosis Off (factory setting)
Note: When the S5U1C63000H2 is started with the self diagnosis on, it takes approx. 5 minuets to be
ready for use.
Open means that the switch lever is at upper side.
On means that it is at lower side.
6
— O P E N —
1
2
3
4
Fig. 2.5.1 Dip switch
SW6
OPEN
9600 bps, 8-bit character, 1 stop bit, no parity (factory setting)
ON
2400 bps, 8-bit character, 1 stop bit, no parity
ON
4800 bps, 8-bit character, 1 stop bit, no parity
ON
19200 bps, 8-bit character, 1 stop bit, no parity
OPEN
38400 bps, 8-bit character, 1 stop bit, no parity
Do not set.
Setting
5
6
7
8
Baud rate setting
EPSON
(S1C63 FAMILY IN-CIRCUIT EMULATOR)
S5U1C63000H2 MANUAL