Push the slot cover into the slot (1).
Ensure that the projection (a) on the slot cover engages into the appropriate recess. If it
!
does not, you will find it difficult to close the locking rail. There is a danger of damage.
Fold the locking rail (3) closed by pressing the clips (2) through the notches on the casing rear
panel from the outside until they engage.
If you have removed the cross-piece, install it now (see "Installing the cross-piece").
Install the fan (see "Installing the side fan").
Close the casing (see "Closing the casing").
If you have installed or removed a PCI board, please check the relevant PCI slot settings
i
in the BIOS Setup . If necessary, change the settings. Further information is provided in the
PCI board documentation.