Fujitsu PCI Gigabit Ethernet User Manual page 66

Pci gigabit ethernet 4.1 update2 / 5.0 for oracle solaris
Table of Contents

Advertisement

No
Message
3
Illegal value for [ParameterName]
4
fail to ddi_dma_bind_handle
5
fail to FragCount
6
fjgi_param_register error
7
fjgi_board_alloc_mem failed !!
8
Error filling TX ring
9
status block can't alloced!
10
status block can't alloced handle!
11
status block can't bind handle!
fjgi_board_init_mem: Failed to
12
dma_alloc !!
13
statistic block can't alloced!
14
hwmib block can't alloced handle!
15
hwmib block can't bind handle!
fjgi_board_init_mem: Failed to dma
16
alloc2!!
17
Illegal value for LinkSpeed_A
18
fjgi_hw_init:Step 22 failed
19
fjgi_hw_init:Step 23 failed
20
fjgi_hw_init:Step 43 failed
21
Can't judge T or SX !!
22
(Other messages)
*1: This appears only when SE0X7GD1X/SE0X7GQ1X/SE0X7GQ2X are used in 1000Mbps environments.
Messages which are reported remotely by the Machine Administration function included in Enhanced Support Facility are listed in the
following table.
Cause
Master: Communicating as
Master
Slave: Communicating as Slave
An error was found with a
parameter defined in the
fjgi.conf file.
The driver could not allocate
DMA resources.
An error was found in message
fragmentation.
The driver could not allocate
resources for the ndd parameter.
The driver could not allocate
resources.
The driver could not allocate
transmit resources.
The driver could not allocate
status information resources.
The driver could not allocate
DMA resources.
The driver could not allocate
statistic information resources.
The driver could not allocate
DMA resources.
The value of LinkSpeed_A in
the configuration file is
incorrect.
An error occurred during
initialization of the adapter.
The adapter type cannot be
recognized.
There is a possibility of driver
internal bug or hardware
failure.
- 60 -
Workaround
Check whether the value is set correctly
in the file.
Installed physical memory may be
insufficient. If this is not the cause, report
this error to your service provider.
Re-activate the interface. If this message
is still displayed, report to your service
provider.
Installed physical memory may be
insufficient. If this is not the cause, report
this error to your service provider.
Set the correct value for LinkSpeed_A.
A hardware failure occurred. Please
contact your service provider.
Check whether the server is supported. If
the system is supported, there is a
possibility of hardware abnormalities.
Please replace the adapter.
Report the error to your service provider.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Se0x7gd2xSe0x7gq1xSe0x7gq2x

Table of Contents