Appendix A Messages; Console Messages From The Driver - Fujitsu PCI Gigabit Ethernet User Manual

Pci gigabit ethernet 4.1 update2 / 5.0 for oracle solaris
Table of Contents

Advertisement

Appendix A Messages

This chapter explains messages displayed by the FUJITSU PCI GigabitEthernet driver.
A.1 Console Messages from the Driver
Messages from the FUJITSU PCI GigabitEthernet driver are listed in the following table.
Table A.1 Console Messages(NOTICE) from the FUJITSU PCI GigabitEthernet Driver
No
1
free send descriptor failed ([detail])
2
(Other messages)
Table A.2 Console Messages(WARNING) from the FUJITSU PCI GigabitEthernet Driver
No
1
soft state alloc failed.
2
Allocation of descriptor memory failed
3
Could not allocate DMA handle
4
Could not bind descriptor memory
5
Multiple fragments in descriptor area
6
Unable to map adapter registers.
7
ddi_get_iblock_cookie-ERROR
8
Unable to install interrupt routine.
9
ATTACH failed
Duplex are invalid !! Please change the
10
partner's duplex Full.
11
Identify failed.
12
ddi_intr_block_enable failed
13
ddi_intr_enable failed
14
ATTACH failed ([detail])
Message
Message
Cause
Freeing of the descriptor to send
failed.
There is a possibility of driver
internal bug or hardware
failure.
Cause
Allocating of the memory
resource failed.
The driver could not allocate
internal resources for DMA.
The driver could not allocate
DMA resources.
An error was found in message
fragmentation.
Mapping of the adapter
registers failed.
The driver could not allocate
interrupt resources.
The driver was not loaded to the
kernel successfully.
With SE0X7GD2X, the remote
device is using half duplex
mode.
Identification of the interface
information failed.
Enabling of the interrupt failed.
Loading of the driver failed.
- 58 -
Workaround
Please report this error to your service
provider.
Report the error to your service provider.
Workaround
Installed physical memory may be
insufficient. If this is not the cause, report
this error to your service provider.
Installed physical memory may be
insufficient. If this is not the cause, report
this error to your service provider.
Re-activate the interface. If this message
is still displayed, report to your service
provider.
Installed physical memory may be
insufficient. If this is not the cause, report
this error to your service provider.
With SE0X7GD2X, only full duplex is
available. Change the duplex mode of the
remote device to Full.
Check whether the system is supported.
If the system is supported, there is a
possibility of hardware abnormalities.
Please replace the adapter.
Try re-enabling the driver. If this
message is still displayed, report to your
service provider.
Installed physical memory may be
insufficient. If this is not the cause, report
this error to your service provider.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Se0x7gd2xSe0x7gq1xSe0x7gq2x

Table of Contents