6.
After the water has been drained,
close the drain valve (clockwise).
The air compressor
can now be
stored.
NOTE: If drain valve is plugged,
release all air pressure.
The valve
can then be removed, cleaned, the
reinstalled.
Air Filter - Inspection
and
Replacement
Risk of Burns.
Compressor head
and cylinder sleeve are very hot.
Do not touch. Allow compressor to
cool prior to servicing.
Risk of Unsafe
Operation. Keep
the air filter clean at all times. Do
not operate the air compressor
with the air filter removed.
A dirty air filter will not allow the
compressor
pump to operate at full
capacity. Before you use the
compressor
pump, check the air filter
to be sure it is clean and in place.
If it is dirty, replace it with a new filter.
On some models,the filter may be
removed by using a pair of needle
nose pliers or a screwdriver. Pull or
pry out the old filter and carefully
clean the filter area. Push in the new
air filter.
Air Compressor
Pump
Intake
and Exhaust
Valves
Once a year have a Trained Service
Technician check the air compressor
pump intake and exhaust valves.
MoOr
The motor has an automatic reset
thermal overload protector. If the
motor overheats for any reason, the
overload protector will shut off the
motor. The motor must be allowed to
cool down before restarting.
The
compressor
will automatically
restart
after the motor cools.
if the overload protector
shuts the
motor off frequently, check for a
possible voltage problem.
Low
voltage can also be suspected when:
1.
The motor does not get up to full
power or speed.
2.
Fuses blow out when starting
the motor; lights dim and remain
dim when motor is started and is
running.
D30050