Owner's
Manuam
PermanentJy
Lubricated
SingJe Stage
PortabJe
AIR COMPRESSOR
o
o
o
o
o
o
o
Safety
Guidelines
Assembmy
Operation
Maintenance
Service
and Adjustments
Repair
Parts
CAUT|ON:
Read the Safety Guidelines
and All instructions
CarefulIy Before
Operating.
Sears,
Roebuck
and Co., Hoffman
Estates,
mL60179
U.S.A.
Visit our Oraftsman website: www.sears.com/craftsman
A10819 Re\J. 0 1d18/05

Advertisement

Table of Contents
loading

Summary of Contents for Craftsman 919.167320

  • Page 1 AIR COMPRESSOR Safety Guidelines Assembmy Operation Maintenance Service and Adjustments Repair Parts CAUT|ON: Read the Safety Guidelines and All instructions CarefulIy Before Operating. Sears, Roebuck and Co., Hoffman Estates, mL60179 U.S.A. Visit our Oraftsman website: www.sears.com/craftsman A10819 Re\J. 0 1d18/05...
  • Page 2: Table Of Contents

    FULL ONE YEAR WARRANTY AIR COMPRESSOR If this CRAFTSMAN Air Compressor fails due to a defect in material or workmanship within one year from the date of purchase, Sears will at its option repair or replace it free of charge= Contact your nearest Sears...
  • Page 3: Glossary

    Model No. 919.167320 Running HP Bore 2.38" Stroke 1.35" Voltage-Single Phase 120V/60HZ Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity Approx. Cutqn Approx. Cut-out SCFM @ 40 psig SCFM @ 90 psig Refer to Glossary for abbreviations. This manual contains information that is important for you to know and understand.
  • Page 4 Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment..WARNING: Risk of explosion or fire What Could Happen How To Prevent mtis normal for eBectrical contacts...
  • Page 5: Accessories

    WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. Now To Prevent What Coumd Happen Failure to properRy drain condensed Drain tank daily or after each use.
  • Page 6 WARNmNG: Risk of Electricam Shock How To Prevent What Coumd Happen Your air compressor is powered Never operate the compressor outdoors electricity. Like any other electrically when it is raining or in wet conditions. powered device, if it is not used Never operate compressor with properly...
  • Page 7 WARNING: Risk of Burns What Could Happen How To Prevent Never touch any exposed metal parts Touching exposed metal such as the on compressor during or immediately compressor head or outlet tubes, can after operation. Oompreasor will remain result in serious burns.
  • Page 8 WARNING: Risk of Serious Injury or Property Damage When Transporting Compressor (Fire, t_halation, Damage to Vehicle Surfaces) How To Prevent What Could Happen OiR can leak or spill and could result in Always place COMPRESSOR on a fire or breathing hazard; serious injury or protective mat when transporting death can result, oil leaks will damage...
  • Page 9 Become familiar with these terms When the tank pressure drops to a certain low level the motor will restart before operating the unit. automatically. The low pressure OFM: Cubic feet per minute. at which the motor automatically SCFM: Standard cubic feet per restarts is called "cut-in"...
  • Page 10 ',,_ iiil ..Unpacking Remove unit from carton and discard all packaging. HOW TO SET UP YOUR UNmT Location of the Air Compressor Make sure the outlet being used has the same configuration ® Locate the air compressor in a the grounded plug.
  • Page 11 Extension Cords Voltage and Circuit Protection Using extension cords is not recom- Refer to the specification chart for the mended. The use of extension cords voltage and minimum branch circuit will cause voltage to drop resulting requirements. in power Ioss to the motor and over- heating.
  • Page 12 Know Your Air Compressor READ THiS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to famiIiarize yourself with the !ocation of various controls and adjustments. Save this manual for future reference. Pressure Sank OutRet Switch Pressure...
  • Page 13 Motor Overload Protector: Air Compressor Pump (not shown): motor has an automatic reset Compresses air into the air tank. Working air is not available until the thermai overioad protector, if the compressor has raised the air tank motor overheats for any reason, the pressure above that required at the overload protector will shut off the air outlet.
  • Page 14 Run the compressor for 15 to Start: minutes. Make sure the drain Turn the On/Auto/Off lever valve is open and there is minimal to "On/Auto" and allow tank air pressure build-up in tank. pressure to build. Motor will After 15 minutes, close the drain stop when tank pressure reaches valve by turning clockwise.
  • Page 15 Customer Responsibilities Before Daily Every or after each each Yearly hours Check Safety Valve Drain Tank Air Filter Air compressor pump intake and exhaust valves 1- more frequent in dusty or humid conditions Risk of Unsafe To Check Safety Valve Operation, Unit Risk of Bursting,...
  • Page 16 IMPORTANT: Do not operate the After the water has been drained, compressor with the air filter removed. close the drain valve (clockwise). The air compressor can now be If dirty, rinse air filter with warm stored. water and squeeze dry. NOTE: If drain valve is plugged, Replace air filter.
  • Page 17 Aimmaintenance and repair Unscrew the check valve (turn operations not misted must be counterclockwise) using a 7/8" performed by Trained Service open end wrench. Note the Technician. orientation for reassembly. Using a screwdriver, carefully Risk of Unsafe push the valve disc up and Operation.
  • Page 18 Assemble the regulator and To Replace Regulator orient as shown. Release all air pressure from air tank, See "To Drain Tank" in the Maintenance section, Set the On/Auto/Off lever to "Off" and unplug unit. Remove the outlet pressure gauge and quick connect (if equipped) from the regulator.
  • Page 19 Before you store the air compressor, _Risk of Bursting. Water will make sure you do the following: condense in the air tank. If not Review the "Maintenance" drained, water will corrode section on the preceding weaken the air tank causing a risk pages and perform scheduled of air tank rupture...
  • Page 20 _Risk of Unsafer Operation. Performing repairs expose voltage sources, moving parts, or compressed air sources. Personal injury may occur. Before servicing: Unpmug or disconnect electricam suppmy to the air compressor, bleed tank of pressure, and allow the air compressor to cool PROBLEM CAUSE CORRECTION...
  • Page 21 PROBLEM OAUSm: CORRECTION Pressure reading it is normal for "some" if there is an excessive on the regulated pressure drop to occur. amount of pressure drop pressure gauge when the accessory is used, drops when an adjust the regulator fo!Iowing accessory ls the instructions in the...
  • Page 22 PROBLEM CAUSE CORRECTION Regulator will Damaged regulator. Replace. not shut off air outlet. Motor will not Let motor cool off and Motor overload protection run. overload switch will switch has tripped. automatically reset. Tank pressure exceeds Motor will start automatically when tank pressure drops pressure switch "cut-in"...
  • Page 23 23-ENG A10819...
  • Page 24 i!!1 Air Compressor Model Number 919,167320 1 Torque 15_25 In-Lbs Torque 100-120 In-Lbs Torque " _-_ 9-12 Ft-Lbs ....9-_@ Torque In-Lbs A10819 24- ENG...
  • Page 25: Assembly

    Nut Sleeve Assembly 3/8 AC-0774 Isolator (3) AC-0292 Outlet Tube SSP=7821 =1 Nut Tubing 3/8 SSG-3105 O=Ring Pump Assembly LA=3069 Label, Craftsman LA=3027 Labet, Drain Tank Eng/Spa LA=3108 Label, Hot Surface D23565 Label, Star Rating D23563 Label, Performance D23138 WheeI 9" (2)
  • Page 26 Air Compressor Model Number 919,167320 Torque 7-10 Ft,qbs, picture shown is for reference onRy. it may differ from actual unit. 83 \ 79-4 Torque 51-63 Un.qbs. ,79-3 j79-2 Torque 42*48 Un.qbs. Torque 100-120 Un.qbs. A10819 26-ENG...
  • Page 27 Air Compressor Mode_ Number 919,167320 PART NUMBER DESCRIPTION SSF-586 Screw 1/4-20 UNC x .75 AC-0108 SSF-615 Screw 1/4-20 UNC-2A Z-AC-0140 Eccentric Bearing Z-D26712 Motor >x 78 Cylinder Sleeve > 79 ..Connecting Rod Assembly >x 79-2 CAC-248-2 Formed Compression Ring >...
  • Page 28 TOTAL DE UN ANO DEL COMPRESOR DE AIRE Si este compresor de aire Craftsman fallase debido a defectos de materiaLes o de fabricaci6n dentro del a_o de su fecha de compra, Sears, a su opcidn, Io reparara o reemplazara sin costo alguno.
  • Page 29 Modelo N ° 919o167320 HP de Trabajo Di_metro interior 2,38 po (60,4ram) Carrera 1,35 po (34,3mm) Tensi6n monof_sica 120V/60HZ/1PH Circuito minimo requerido Tipo de fusibleAcci6n retardada Capacidad de aire en el tanque 33 Galones (124,9 litros) Presi6n de corte de entrada Presi6n de corte de salida 8,6 Calibre de libras SCFM a 40 psig...
  • Page 30 GUARDE ESTAS |NSTRUCCiONES La operaci6n o el mantenimiento inadecuados de este producto podrian ocasionar lesiones serias y dafios a la propiedad. Lea y comprenda todas las advertencias instrucciones de funcionamiento antes de utilizar este equipo. ADVERTENCIA: Riesgo de E×plosi6n o mncendio _,Qu_ puede occurrir? gO6mo...
  • Page 31 ADVERTENCIA: Riesgo deExplosi6n I'll Tanque de aire: las siguientes condiciones podrfan, causar el debilitamiento del tanque, causar su explosi6n violenta, davies a la propiedad o lesiones serias. _,Qu_ puede occurrir? _C6mo prevenirlo? El drenaje iuadecuado del agua coudensada Drene eUtanque diariamente o despues ee el taeque...
  • Page 32 ADVERTENCIA: Riesgo Descarga ER_ctrica I_.._ ;,C6mo _,Qu6 puede occurrir? prevenirlo? Su compreeor de aire est& accionado dam_s opere el oompresor a la intemperie e_ectricidad. Como cualquier otro dispositivo cuando estA Hoviendo o en condiciones electrico accionado electricamente, si no se Io humedad.
  • Page 33 ADVERTENCIA: Riesgo de Quemaduras ,_Qu_ puede occurrir? LO6mo preveniHo? Jam_s toque partee de metal expueetas eo eU Tocar eUmetaU expuesto ta_ como el cabeza_ compresor durante o inmediatamente despu6s de! compresor o los tubos de salida del escape, de la operaci6n. EJ compreser permanecer_ puede...
  • Page 34 ADVERTENOIA: Riesgo de Lesiones Serias o DaSos a la Propiedad Transportar el ¢ornpresor (Fuego, hhaUaci6n, da6o a la superficie de veh_cuUos) _,Qu_ puede occurrir? _,C6mo preveniHo? EU aceite puede derramarse generando un ties- Depoeite el compresor sobre una aUfombrHla go de incendio o inha]ac}6n que puede causar protectora cuando...
  • Page 35 Presi6n minima de corte: Cuando el Familiarfcese con los siguientes t6rminos, motor est_ apagado, la presi6n del tanque antes de operar la unidad: de aire baja a medida que usted continOa CFM: (Cubic feet per minute) Pies cObicos usando su accesorio. Cuando la presi6n pot minuto.
  • Page 36 Desempaque Extraiga la unidad de su caja y descarte todas Ins partes de embalaje. iii ..C6MO PREPARAR LA UNIDAD IMPORTANTE: El tomacorriente que ser_ utilizado deber_ haber side conectado a tierra conforme a todos los c6digos Ubicacidn deB compresor de aire locales y ordenanzas.
  • Page 37 Cables d e extensi6n e[_ctrica Protecci6n del voJtaje y del circuito No se recomienda la utilizaci6n de cables Acerca del voltaje y la mfnima cantidad de de extensi6n electrica. El uso de cables circuitos requeridos, refi6rase al cuadro de de extensi6n el6ctrica originarA una especificaciones.
  • Page 38 Conozca su compresor Qire LEA ESTE MANUAL DEL PROPETARiO Y SUS NORMAS DE SEGURiDAD ANTES OPERAR LA UNIDAD. Compare las ilustraciones contra su unidad a fin de familiarizarse la ubicaci6n de los distintos controles y regulaciones. Conserve este manual para referencias futuras.
  • Page 39 Protector de sobrecalentamiento Bemba de compresi6n demaire (no mostrada}: Comprime el aire dentro del motor (no mostrado}: El motor tiene tanque. El aire de trabajo no se encuentra un reposicionado autom_tico para la disponible hasta que el compresor haya protecci6n t6rmica, Si pot cualquier raz6n alcanzado a Ilenar el tanque hasta un nivel el motor se recalentara, el protector...
  • Page 40 Haga funcionar el compresor durante 15 C6mo porter en marcha: minutos. AsegOrese de que la vAIvula de drenaje est_ abierta y que la presi6n de Mueva la palanca On/Auto/Off a la posici6n "On/Auto" y deje que se aire acumulado en el tanque sea minima. incremente la presi6n del tanque.
  • Page 41 Responsabilidades dem ciiente Antes Diadamente Cada Anualmente de cada oluegode cada uso horas Verifique la vAIvula de seguridad Drenaje del tanque Filtro de aire VAIvulas de entrada y escape de la bomba del compresor de aire 1- MAs frecuente en condiciones )olvorientas o hOmedas.
  • Page 42 Retire el filtro de aire y asegOrese de Una vez drenada el agua, cierre que este limpio. v_lvula de drenaje (sentido horario). Ahora el compresor de aire podrA ser IMPORTANTE: No opere el compresor guardado. el filtro de aire. NOTA: Si la vAIvula de drenaje fuera del Siesta sucio enjuague el filtro de aire tipo enchufe, elimine toda la presi6n...
  • Page 43 Todo tipo de rnantenimiento Desenrosque la v_lvula de retenci6n operaciones de reparaci6n girAndola hacia la izquierda usando meneionados, deber&n set efeetuados una Ilave de boca de 7/8 plug. per personaR t6cnico especializado. (22 mm). Tome nota de la orientaci6n para volverla a Riesgo de ensamblar.
  • Page 44 Ensamble el regulador y ori6ntelo de Para reemplazar el regulador acuerdo a Io mostrado. Libere toda la presi6n del aire del tanque. Vea "Drenaje del tanque" en la secci6n "Mantenimiento". Apagar la unidad colocando interruptor en On/Auto/OFF en "Off". Usando una Ilave de tuercas ajustable retire el medidor de salida de presi6n y la conexi6N rApida del regulador (si la tiene).
  • Page 45 Antes de guardar su compresor de aire, Riesgo de asegOrese de hacer Io siguiente: Explosi6n. El agua Revise la secci6n "Mantenimiento" se eondensa dentro del tanque de aire. de las p_ginas precedentes y ejecute Si no se drena, ella el mantenimiento programado corroer_ debilitando...
  • Page 46 mantenimiento, el operador puede quedar expuesto a fuentes de corriente y de aire comprimido o a piezas movibles. Antes de intentar hacer reparaciones, desconectar el compresor deBtomacorriente, drenar la presi6n de aire del tanque y esperar a que el compresor se enfr_e.
  • Page 47 CORRECCJ6N PBOBLEMA CAUSA Si hubiese una cakta excesiva La lectura de la Es normal que ocurra algOn de presi6n durante el uso del presi6n sobre un descenso en la presi6n. accesorio, ajuste el regulador de man6metro acuerdo alas instrucciones de la viene equipado secci6n Operaci6n.
  • Page 48 CAUSA CORRECCION PROBLEMA El motor no Deje enfriar el motor y el El interrupter de protecci6n funciona. obrecarga del motor se ha interruptor de sobrecarga se abierto. reajustarA automAticamente. El motor arrancarA automAticamente La presi6n del tanque excede cuando la presiOn del tanque caiga la presi6n de "corte mAximo"...
  • Page 49 49-SP A10819...
  • Page 50 A10819 50-SP...
  • Page 51: Installation

    Contratos Proteeei6n para Reparaciones Congratulations on making a smart Felicitac/ones per hacer una compra purchase. Your new Craftsman ® product inteligente. Su nueva unidad Craftsman @ esta is designed and manufactured for years diseSada y fabricada para afios de operaci6n of dependable operation.
  • Page 52 Your Home For repair - in your home - of all major brand appHiances, 0 Sears, Roebuck and Co (,_)Registered Trademark / TM Trademark / s_ Service Mark of Sears, Roebuck and Co (.) Mama Registrada / TM Marca de Fabrica / s_,l Marca de Servicio de Sears,...

Table of Contents