Download Print this page

Craftsman 919.167462 Owner's Manual page 13

Permanently lubricated single stage side stack air compressor

Advertisement

Available languages

Available languages

Cooling System (not shown): This
compressor contains an advanced
design cooling system. At the heart of
this cooling system is an engineered
fan. It is perfectly normal for this fan
to blow air through the vent holes in
large amounts. You know that the
cooling system is working when air is
being expelled.
Air Compressor
Pump:
Compresses air into the air tank.
Working air is not available until the
compressor
has raised the air tank
pressure above that required at the
air outlet.
Drain Valve: The drain valve is
located at the base of the air tank
and is used to drain condensation
at
the end of each use.
Check
Valve
Drain
Valve
Check Valve: When the air
compressor
is operating, the check
valve is "open", allowing compressed
air to enter the air tank.
When the air
compressor
reaches "cut-out"
pressure, the check valve "closes",
allowing air pressure to remain inside
the air tank.
Pressure Release Valve:
The
pressure release valve located on the
side of the pressure switch, is
designed to automatically
release
compressed
air from the compressor
head and the outlet tube when the air
compressor
reaches "cut-out"
pressure or is shut off. The pressure
release valve allows the motor to
restart freely. When the motor stops
running, air will be heard escaping
from this valve for a few seconds.
No
air should be heard leaking when the
motor is running, or continuous
leaking after unit reaches "cut-out"
pressure.
Pressure
Release
Valve
How to Use Your Unit
How to Stop:
1.
Set the On/Auto/Off
lever to
"OFF".
Before
Starting
Break-in instructions
_Risk
of Unsafe
Operation. Serious
damage may result if the following
break-in instructions are not
closely followed,
This procedure is required before the
air compressor is put into service and
when the check valve or a complete
compressor
pump has been
replaced.
1.
Make sure the On/Auto/Off
lever
is in the "OFF" position.
NOTE: If quick connect is installed,
pull coupler back until it clicks to
prevent air from escaping through the
quick connect.
2.
Plug the power cord into the
correct branch circuit receptacle.
(Refer to Voltage and Circuit
Protection paragraph
in the
Installation section of this
manual.)
3.
Open the drain valve fully
(counter-clockwise)
to permit air
to escape and prevent air
pressure build up in the air tank
during the break-in period.
4.
Move the On/Auto/Off
lever to
"ON/AUTO"
position. The
compressor
will start.