Physical/Environmental Specifications
Table
A‐2 provides physical and environmental specifications for the 8‐Port
(BL‐69108ENT) and 24‐Port (BL‐69524ENT) Mid‐Span Power Hubs.
Table A-3 Physical and Environmental Specifications
Item
Operating Temperature
Storage Temperature
Relative Humidity
Operating Altitude
Electrical Specifications
AC Power Input
Voltage
Connector
Chassis grounding
Power supply
DC Port Power Output
Power enabling
Power pins
Maximum power/port
Maximum power, all ports active
Module-to-module isolation
Overload protection
Specification
0° C to 40° C (32° to 105° F)
-10° C to 60° C (14° F to 140° F)
10% to 90% non-condensing
-1,000 to 10,000 feet
90–264 V autoranging (46 Hz–63 Hz)
3-pin with ground
yes
single
IEEE 802.3af
Unused pairs, pins 4,5(+), 7,8(-)
15.6 W
24 ports at 15.6 W each
1500 Vrms
If current reaches 400–450 mA for 300–400
milliseconds, then the port shuts down.