MAINTENANCE
Section 4 - Maintenance
1S kW Generator
@ 4.11.1 ADDITIONAL CORROSION
PROTECTION
Periodically
spray
all engine
linkage
parts
and
brack-
ets with
corrosion
inhibiting
spray
such
as WD=40
or
a comparable
product.
4.12
OUT OF SERVICE PROCEDURE
@
4o12.1REMOVAL FROM SERVICE
If the generator
cannot
be exercised
every
seven
days,
and
will be
out
of service
longer
than
90 days,
pre-
pare
tile generator
Ior storage
as Iollows:
1.
Start
the engine
and
let it warm
tip.
2.
Close
the fuel shutoff
valve
in the fuel
supply
line
and
allow
the unit
to shut
down.
3.
Once
the
unit
has
shut
down,
it will
signal
a low
oil fault.
4.
Set
the
generator's
main
circuit
breaker
to its
OFF
(or open)
position.
5.
Set
the
Auto/Oft/Manual
switch
to
OFF
and
turn
off the
utility
power
to the
transfer
switch.
Remove
the
7.5A and
15A fllses
from
the genera=
tor
control
panel.
Disconnect
the battery
cables
as outlined
in "General
Hazards"
{page
2). Turn
on the utility
power
supply
to the
transfer
switch
in order
to power
the emergency
load
centers
cir-
cuits
while
utility" power
is awJilable.
G.
While
the
engine
is
still
warm
from
running,
drain
the oil completely.
ReIill
the crankcase
with
oil. See
"Engine
Oil Recommendations,"
Section.
7.
Attach
a tag to the
engine
indicating
the viscosity"
and
classification
of the oil in the
crankcase.
8.
Remove
the
spark
plug(s)
and
spray
fo_ging
agent
into
the
spark
plug(s)
threaded
openings.
Reinstall
and
tighten
the
spark
plug(s).
9.
Remove
the
battery
and
store
it in
a cool,
dry
room
on a wooden
board.
Never
store
the battery
on any
concrete
or earthen
floor.
10. Clean
and
wipe
the entire
generator.
4o12o2 RETURN TO SERVICE
To return
the
unit
to service
after
storage,
proceed
as follows:
1.
Verify
that
utility
power
is turned
off and
that
the
Auto/Off/Manual
switch
is set to OFF
2.
Check
the
tag on the
engine
for
oil viscosity-
and
classification.
Verify"
that
the
correct
reeom=
mended
oil is used
in the engine
(see "Engine
Oil
Recommendations").
If necessary,
drain
and
refill
with
the proper
oil.
3.
Cheek
the
state
of the
battery.
Fill
all
cells
of
unsealed
batteries
to the
proper
level
with
dis°
tilled
water.
DO
NOT
USE
TAP WATER
IN THE
BATTERY.
Recharge
the
battery
to
I00
percent
state
of charge,
or, if defective,
replace
the
bat=
tery.
See the "Specifications"
Section,
ior type and
size.
4.
Clean
and
wipe
the entire
generator.
5.
Remove
the
7.5A and
15A fuses
Kom
the genera=
tor control
panel.
Reconnect
the battery.
Observe
battery
polarity.
Damage
may
occur
if the battery
is connected
incorrectly.
6.
Open
the iuel
shutoff
valve.
7.
Insert
the
7.5A
and
15A fuses
into
the generator
control
panel.
Start
the unit
by moving
the Auto/
Off/Manual
switch
to MANUAL.
Allow
the unit
to
warm
up thoroughly.
8.
Stop
the
unit
by
setting
the
Auto/Off/Manual
switch
to OFF
9.
Turn
on the utility
power
to the transfer
switch.
10. Set the Auto/Off/Manual
switch
to AUTO.
1 1. The
generator
is now
ready
Ior
service.
NOTE:
If the battery
was dead
or disconnected,
the exer-
cise timer
must
be reset,
2O