Carrier ASPB07-1SI Installation Manual
Carrier ASPB07-1SI Installation Manual

Carrier ASPB07-1SI Installation Manual

Carrier automatic home standby generators installation guide

Advertisement

Quick Links

®
Turn to the Expertg
Installation
Guide
This Installation
Guide is intended to be
used in conjunction
with the Owner's
Manual.
The Owner's Manual must first be read
thoroughly
prior to installation
of the Home
Standby generator.
A_ intended for outdoor installation
only.
A_ Not intended
for life support
applications.
c_0s
LISTED

Advertisement

loading

Summary of Contents for Carrier ASPB07-1SI

  • Page 1 Turn to the Expertg Installation Guide This Installation Guide is intended to be used in conjunction with the Owner's Manual. The Owner's Manual must first be read thoroughly prior to installation Standby generator. A_ intended for outdoor installation A_ Not intended for life support applications.
  • Page 2 ELECTRICAL INTERCONNECTION DRAWING ® Turn to the Expertg N1 N2 23 194 GENERATOR GROUND (LOCATED ON THE REAR OF UNIT) GENERATOR OUTPUT CIRCUmT BREAKER 2 POLE \EARTH SPIKE "_...
  • Page 3 TO HOUSE BRANCH CiRCUiTS SPLICED USING WiRE NUTS EMERGENCY CiRCUiTS IllU 40A OR 70A 2-POLE CIRCUIT BREAKER SERVICE CONNECTION EXTERNAL CUSTOMER 4 PmN CONNECTOR UL LISTED PANEL BOARD (8,10,12 OR 16 CIRCUIT TRANSFER SWITCH) CONNECTION OF GENERATOR TO EXTERNAL CONNECTION PANEL...
  • Page 4: Read This Manual Thoroughly

    Parts of the generator are rotating and/or hot duringoperation. Exercise carenearrunning generators. Forsafetyreasons, CARRIER r ecommends that the installation,initial start up and maintenance o f this equipment i s carriedout bya Dealer. The engine exhaustfumes contain carbon monoxide, which can be DEADLY.
  • Page 5: Electrical Hazard

    Never use t he generator orany o fitsparts a sastep. Stepping canstress a nd break p arts, andmay result indangerous conditions from leaking exhaust gases, fuelleakage, ELECTRICAL HAZARD All generators coveredby this manualproducedangerous electrical voltagesand can causefatal electricalshock.Utility powerdelivers extremely high and dangerous voltagesto thetransfer switchas does the standbygenerator w henit is in operation.
  • Page 6 It will be necessary to paya visit to your local municipaloffices to applyfor a building permit. Building permitsare necessary to ensure proper installation, safety and adherenceto all local building code specifications.The location and phone number can befoundin the government s ectionof yourlocal phonebook. Plan the location of your generator.NOTE: Do not place the generatordirectlyunder a window.Selectan area outside of your homenearestyour incominggas service.
  • Page 7 Theouterdiameter o f thethreaded endis 15/16". lOa. Determinewherethe flexible conduit will pass through the housefrom inside to outside. Whenyouare certainyouhaveclearance on eachsideand within the wall, drill a small pilot holethrough the wall to markthe location. lOb. Using a hole saw,drill a 1-3/4 inch diameterhole in the house'swall to allow the conduit to fit through.
  • Page 8 - continuedfrompage7 Wire nut the black wire to the matching circuit lead wire from the emergency circuit breakerfrom load center in the transferswitch.(Allcircuit wiresare color coded labeled identification). UL approved wire Iocknuts are included in installation kit. Tracethe black (hot)wireyou havejust connected backto the sameRomex cable(circuit)to find itsmating white(neutral)wire.Wirenutthis wireto the matchingcircuitnumber on the white (neutral)wire comingfrom the emergency load center.