5-8
Dell PowerEdge 6350 Systems Installation and Troubleshooting Guide
7DEOH  2SWLRQ 3DUDPHWHUV
Number of
0001 through 9999, or 0000, which loops indefinitely until
Times to Repeat
you press <Ctrl><Break>. The default is 1.
Test(s)
Maximum Errors
0000 through 9999, where 0000 means that there is no error
Allowed
limit. The default is 1.
Pause for User
Yes, No
Response
Allows you to decide whether tests will wait for user input.
The default is Yes to wait for user input.
Output Device
Display, Printer, File
for Status
If you have a printer attached to the computer, you can use it
Messages
to print the status messages, if any, that are generated when
a test runs. (The printer must be turned on and in the online
mode to print.) If you select File, the messages are printed to
a file named result on a diskette in drive A. The default is
Display.
Output Device
Display, Printer, File
for Error
This parameter has the same effect as the Output Device
Messages
for Status Messages parameter, except that it pertains only
to error messages. The default is Display.
This parameter specifies the number of times the tests run when you select Run. To
change the default, type the desired value. If you type 0 (zero), the tests will run
indefinitely.
This parameter specifies the maximum number of errors that can occur before testing
is stopped. The error count begins from zero each time you run a subtest or test
group individually or each time you select All to run all of them. To change the default,
type the desired value. If you type 0 (zero), you are specifying that there be no limit on
the number of errors that can occur—testing will not be stopped, regardless of the
number of errors.
If this parameter value is set to Yes, the diagnostics pauses when one of the following
occurs:
Your interaction is needed to verify the Video Test group screens or the Keyboard
Test group key functions, or another type of interaction, such as inserting a dis-
kette, is required.
The maximum error limit is reached.
If the Pause parameter is set to No, the diagnostics ignores some subtests that
require your interaction; certain subtests can run only if this option is set to Yes