Timer chip
counter 2
failed
Unexpected
interrupt in
protected mode
Unsupported CPU
detected in
SLOT n
Unsupported CPU
speed in CMOS
Write fault
Write fault on
selected drive
NOTE: For the full name of an abbreviation or acronym used in this table, see the abbreviation and
acronym list that precedes the Index.
FRQWLQXHG
Defective system board
Faulty or improperly
seated DIMM, DIMMs
not installed in sets of
four, a faulty or improp-
erly seated memory
module, or a defective
system board
Microprocessor not sup-
ported by system
Microprocessor not sup-
ported by BIOS
Faulty diskette or hard-
disk drive
Replace the system board.
See Chapter 12, "Getting
Help," for instructions on
obtaining technical assistance.
Be sure that the DIMMs are
installed in sets of four and in
the proper sockets for each
memory bank in use. If this
does not resolve the problem,
remove and reseat the DIMMs
and the memory module. If the
problem persists, replace the
DIMMs or the memory mod-
ule. See "Adding Memory" in
Chapter 8 for instructions on
installing or removing DIMMs
or the memory module. If the
problem still persists, replace
the system board. See
Chapter 12, "Getting Help,"
for instructions on obtaining
technical assistance.
Install a correct version of the
microprocessor in the
specified microprocessor
connector. See Chapter 8,
"Installing System Board
Options," for instructions.
Upgrade the BIOS. See
Chapter 4, "Using the System
Setup Program," in the
system User's Guide for
instructions.
Replace the diskette or hard-
disk drive.
Messages and Codes
3-9