Other Status Read Command; Error Code Table - Sanyo PLC-XC50 - 2600 Lumens Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-XC50 - 2600 Lumens:
Table of Contents

Advertisement

PLC-XC50/55 Expand Serial Command Functional Specifications

6.9 Other Status Read Command

Status read command
CR_STATUS[CR]
CR_SIGNAL[CR]
CR_VMUTE[CR]
CR_FREEZE[CR]
CR_PTIMER[CR]
CR_TEMPWARN[CR]
CR_TEMP[CR]
CR_TEMPFAIL[CR]

7. Error Code Table

Error Code
?
101
102
103
201
301
302
402
Note) These error codes are applied to Expand Command, not to Basic Command
Item
Get setting status of Projector behavior
Get Signal Status if there is a signal or not
Get setting status of No Show
Get setting status of Freeze
Get the operating status of Presentation Timer
Get if temperature is close to abnormal temperature
Get current temperature status
Get temperature when sensors approach abnormal
temperature
Contents
-When the received data cannot be decoded
-Parameter determination error (digit number error,
including invalid value, etc.)
The function is not available in the selected Mode
Selected value is out of range (Not reflected)
Command mismatched to Hardware (command for
Optional function which is not installed)
When reached upper or lower limit of increasing or
decreasing data
Command cannot be executed during capturing
display. Resend the command after a while
Command cannot be executed during Auto PC
adjust operation. Resend the command after a while
Command cannot be executed during PIN code
operation. Resend the command after a while.
14/67

Advertisement

Table of Contents
loading

Table of Contents