Setting Status Read Command; Cr_Lang Command; Cr_Autosetuppcadj Command; Cr_Inputsearch Command - Sanyo PLC-WL2503 - 2500 Lumens Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-WL2503 - 2500 Lumens:
Table of Contents

Advertisement

PLC-WL2500 / WL2501/ WL2503 Expand Serial Command Functional Specifications

9.11 Setting Status Read Command

9.11.1 CR_LANG Command

Command
"CR_LANG"[CR]
Details
Get selected language
Acceptable
Response
Unacceptable

9.11.2 CR_AUTOSETUPPCADJ Command

Command
"CR_AUTOSETUPPCADJ" [CR]
Details
Get Auto PC adj. setting status in Auto setup
Acceptable
Response
Unacceptable

9.11.3 CR_INPUTSEARCH Command

Command
"CR_INPUTSEARCH"[CR]
Details
Get setting status of Input search
Acceptable
Response
Unacceptable
"000_%a"[CR]
"ENG" --------------------------- Select English
"DEU" --------------------------- Select German
"FRA" --------------------------- Select French
"ITA" ----------------------------- Select Italian
"ESP" ---------------------------- Select Spanish
"POR" --------------------------- Select Portuguese
"NED" --------------------------- Select Dutch
"SVE" --------------------------- Select Swedish
"FIN" ---------------------------- Select Finnish
"NOR" -------------------------- Select Norwegian
"DAN" -------------------------- Select Danish
%a
"POL" --------------------------- Select Polish
"HUN" --------------------------- Select Hungarian
"ROM" -------------------------- Select Romanian
"RUS" --------------------------- Select Russian
"BRA" --------------------------- Select Brazilian Portuguese
"TUR" --------------------------- Select Turkish
"ARA" --------------------------- Select Arabic
"KAZ" --------------------------- Select Kazak
"CHI" ---------------------------- Select SimpllifiedChinese
"HON" -------------------------- Select Traditional Chinese
"KOR" -------------------------- Select Korean
"JPN" --------------------------- Select Japanese
"Error code"[CR]
"000_%a"[CR]
"ON" ------------------ Auto PC ADJ. in Auto setup is ON
%a
"OFF" ----------------- Auto PC ADJ. in Auto setup is OFF
"Error code"[CR]
"000_%a"[CR]
"OFF" --------------------- Input search is OFF
%a
"ON1" --------------------- Input search is On1
"ON2" --------------------- Input search is On2
"Error Code"[CR]