2-32 Color Calibration
15. On the Control Panel, choose OK.
Status messages display the progress of scanning and calculating measurements.
16. When prompted to Print Comparison Page (Expert Mode only), choose Yes to print a
preview of the selected calibration.
Choose from a list of output profiles that use the same calibration set and press OK.
This option appears only in Expert Mode calibration.
17. When prompted to apply or overwrite the calibration, choose Yes.
18. Choose Yes to confirm.
Status messages display progress information. When calibration is complete, the
Control Panel display returns to the Functions menu.
T
O REMOVE CALIBRATION FROM THE
1. From the Fiery X3e Control Panel, access the Calibration menu as described on
page
2-30.
2. Choose Remove Calibration.
3. When prompted, verify that you want to proceed with removing calibration.
The current measurements are removed and a default calibration is restored.