Lowvoltage insulatedceiling(type-1c) frame-in-kits

Advertisement

READ AND UNDERSTAND THESE INSTRUCTIONS bEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local
regulations. To assure full compliance with local codes and regulations, check with your local electrical
inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
INSULATED CEILING (TYPE-1C) FRAME-IN-KITS: C4AICLV, C6AICLV
TRANSFORMER REPLACEMENT
• Make sure power to fixture is off.
• Remove REFLECTOR TRIM from ceiling by twisting counter-clock-
wise and pulling down.
• Disconnect & remove SOCKET HARNESS from TRANSFORMER
ASSEMBLY.
• Disconnect POWER SUPPLY HARNESS: For C4AICLV disconnect
harness at TRANSFORMER COVER. For C6AICLV disconnect har-
ness from junction box assembly (opposite side of fixture from
TRANSFORMER ASSEMBLY).
• Remove (2) THUMB SCREWS.
• Remove TRANSFORMER COVER from THUMB SCREW studs
• Pull TRANSFORMER ASSEMBLY and TRANSFORMER COVER into
FIXTURE HOUSING and out through aperture opening.
• Disconnect TRANSFORMER wiring from THERMAL PROTECTOR(S)
and TRANSFORMER CONNECTORS. Refer to TRANSFORMER
WIRING DIAGRAMS shown below for your particular MODEL AS
INDICATED.
• Remove TRANSFORMER MOUNTING HARDWARE and discard faulty
TRANSFORMER.
• Install new TRANSFORMER in reverse order of removal.
WARNING: Risk of fire. Fixture contains THERMAL PROTECTORS that
must be rewired as shown in DIAGRAMs below. Use only
replacement TRANSFORMER obtained from LIGHTOLIER
WHITE
WHITE
THERMAL
PROTECTORS
PRI
TRANSFORMER
TRANFORMER WIRING DIAGRAM
MODEL C4AICLV
INSTALLATION PROCEDURE FOR LOW VOLTAGE
WHITE
BLACK
POWER SUPPLY
HARNESS CONNECTOR
RED
WHITE
RED
WHITE
SEC
SOCKET HARNESS
CONNECTOR
TRANSFORMER
COVER
TRANSFORMER
CONNECTOR
THUMB SCREW
FIXTURE
HOUSING
TRANSFORMER ASSEMbLY
NOTE: 1. LOW VOLTAGE FIXTURES should be dimmed only
with special dimmers intended specifically for that purpose.
Use Lightolier Lytemode, Scenist, Crescendo VA, Neptune VA,
Precision VA, EasySet VA, Sunrise VA, Radiant VA or equiva-
lent products by others or variable autotransformers or elec-
tronic dimmers intended for use with low voltage fixtures.
2. Low voltage fixtures produce audible sound which may be
objectionable in acoustically critical areas.
BLACK
WHITE
THERMAL
PROTECTORS
WHITE
BLACK
RED
PRI
TRANFORMER WIRING DIAGRAM
MODEL C6AICLV
LIGHTOLIER a GENLYTE THOMAS company.
631 Airport Road, Fall River, MA 02720
INSTRUCTION SHEET NO.
IS:CICLV
A1099 Page 2 of 2
TRANSFORMER
TRANSFORMER
MOUNTING HARDWARE
TRANSFORMER
HOUSING
WHITE
BLACK
RED
BLUE
WHITE
WHITE
RED
WHITE
WHITE
WHITE
SEC
POWER
SUPPLY
CONNECTOR
(TO J-BOX)
SOCKET
HARNESS
CONNECTOR
5.5 V
SOCKET
HARNESS
CONNECTOR