Hitachi L100DN DeviceNet Series Addendum Read This First Manual page 81

Table of Contents

Advertisement

Standard Functions
"A" Group Parameters
Func.
Name
Code
A_02 Run command source setting
A_03 Base frequency setting
A_04 Maximum frequency setting
A_20 Multi-speed 0 setting
A_21 Multi-speed 1 setting
A_22 Multi-speed 2 setting
A_23 Multi-speed 3 setting
A_24 Multi-speed 4 setting
A_25 Multi-speed 5 setting
A_26 Multi-speed 6 setting
A_27 Multi-speed 7 setting
A_28 Multi-speed 8 setting
A_29 Multi-speed 9 setting
A_30 Multi-speed 10 setting
A_31 Multi-speed 11 setting
A_32 Multi-speed 12 setting
A_33 Multi-speed 13 setting
A_34 Multi-speed 14 setting
A_35 Multi-speed 15 setting
A_38 Jog frequency setting
A_39 Jog stop mode
A_41 Torque boost method selection
DeviceNet Class ID = 101
Inst Attr Size
Range
1
102
1
1 Control
terminal
2 Run key on
keypad
1
103
2
50Hz to maximum
frequency
1
104
2
Base freq. to
360Hz
1
120
2
0.00 – 360.00Hz
1
121
2
0.00 – 360.00Hz
1
122
2
0.00 – 360.00Hz
1
123
2
0.00 – 360.00Hz
1
124
2
0.00 – 360.00Hz
1
125
2
0.00 – 360.00Hz
1
126
2
0.00 – 360.00Hz
1
127
2
0.00 – 360.00Hz
1
128
2
0.00 – 360.00Hz
1
129
2
0.00 – 360.00Hz
1
130
2
0.00 – 360.00Hz
1
131
2
0.00 – 360.00Hz
1
132
2
0.00 – 360.00Hz
1
133
2
0.00 – 360.00Hz
1
134
2
0.00 – 360.00Hz
1
135
2
0.00 – 360.00Hz
1
138
2
0.5 – 9.99Hz
1
139
1
0 Free-run stop
1 Controlled
deceleration
2 DC braking to
stop
1
141
1
0 Manual torque
boost
1 Automatic
torque boost
L100DN Inverter
Get/
Scaling
Set
G/S
1
G/S
1
G/S
100
G/S
100
G/S
100
G/S
100
G/S
100
G/S
100
G/S
100
G/S
100
G/S
100
G/S
100
G/S
100
G/S
100
G/S
100
G/S
100
G/S
100
G/S
100
G/S
100
G/S
G/S
G/S
81

Advertisement

Table of Contents
loading

Table of Contents