"A" Group: Standard Functions - Hitachi L100 Series Quick Reference Manual

Hide thumbs Also See for L100 Series:
Table of Contents

Advertisement

"A" Group: Standard Functions

Func.
Code
A_01
Frequency source setting
• 00 Keypad potentiometer
• 01 Control terminal
• 02 Function F_01 setting
A_02
Run command source setting
• 01 Input terminal FW or RV (assign-
able)
• 02 Run key on keypad, or digital
operator
A_03
Base frequency setting
A_04
Maximum frequency setting
A_11
O/OI–L input active range start
frequency
A_12
O/OI–L input active range end frequency
A_13
O/OI–L input active range start voltage
A_14
O/OI–L input active range end voltage
A_15
O/OI–L input start frequency enable
• 00 Use A_11 starting value)
• 01 Use 0 Hz
A_16
External frequency filter time constant
A_20
Multi-speed frequency setting
A_21
Multi-speed frequency settings
A_22
A_23
A_24
A_25
A_26
A_27
A_28
A_29..
..A_35
A_38
Jog frequency setting
A_39
Jog stop mode
• 00 Free-run stop, jogging disabled
during motor run
• 01 Controlled deceleration, jogging
disabled during motor run
• 02 DC braking to stop, jogging
disabled during motor run
Name / Description
15
Default
Value
–FE / –FU /
–FR
01 / 01 / 00
01 / 01 / 02
50.0 / 60.0 /
60.0
50.0 / 60.0 /
60.0
0.0
0.0
0
100
01
8
0
0 / 0 / 5
0 / 0 / 10
0 / 0 / 15
0 / 0 / 20
0 / 0 / 30
0 / 0 / 40
0 / 0 / 50
0 / 0 / 60
0 / 0 / 0
1.0
00
Set
Value

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L100-m series

Table of Contents