Diagnostic Codes

The diagnostic codes may be a single byte or pair of bytes displayed in hex.
The following tables for each controller list the bit positions defined for each
byte. A 1 bit indicates a failure. Diagnostic codes are computed by summing the
value for each bit position using hexadecimal arithmetic.

IntelliTouch Serial Controller (2500S)

These controllers have a two-byte diagnostic code displayed in the form AA-
BB. The AA byte is defined below. The BB byte is the same as the 4035
controller, defined above in Table A.1.
AA Bit
7
6
5
4
3
2
1
0
Table A.3

The IntelliTouch Serial Controller (2500S) bit position relating to each byte.

Value (hex) Description
80
Touch microprocessor test incomplete
40
Reserved
20
Touch microprocessor test failed—touchscreen may not be
connected
10
Nonvolatile RAM checksum test failure
08
RAM read/write test failure
04
ROM checksum test failure
02
Microprocessor logic/register test failure
01
Firmware/hardware compatibility test failure