3. Connect the
with a CAT5 cable.
Ceiling Plate
(
RS-232 Serial Cable
4. For use with the AP-60: connect the IR emitter to the two-position captive screw
IR output on the ceiling plate. You may connect the emitter directly, or extend the
IR emitter with a two-conductor cable. Pull the IR cable through the face plate to
the AP-60 and attach the IR emitter bud to the IR receiver window on the speaker
near the microphone nobs. Use the IR Bud Holder to facilitate projector service.
5. Connect the female DB9 on the ceiling plate to the serial control port of the pro-
jector with a straight male-to-female RS-232 serial cable (not included).
6. Thread the 6 VDC power supply through the opening in the ceiling plate and
plug it into the power supply barrel receptacle.
7. Mount the PixiePlus to a single-gang wall box (not included) or appropriate
mounting location. The inner screw holes on the PixiePlus should be used to
anchor the unit to the wall box. The outer screw holes will be used to affix a
Decora™ wall plate over the face of the PixiePlus.
8. Once all the connections are made, plug in the PixiePlus power supply wall wart
to the electrical box.
The PXE-DCM+ is a low-voltage device. Never install the PixiePlus in an
electrical back box containing high-voltage wiring. This would cause a seri-
ous electrical danger and violate United States national electrical codes.