Stylus Pro Service Manual
Item
Rated voltage
Input voltage range
Rated frequency range
Input frequency range
Rated current
Power consumption
Insulation resistance
Dielectric strength
1.2.6 Environmental Conditions
Table 1-7. Acceptable Environmental Conditions
Description
Temperature
Humidity
Shock resistance
Vibration resistance
*1 : For operating the printer, conditions must be in the range shown in the figure below.
2
*
: These conditions are acceptable when the printer is in its shipping container.
3
*
: Without condensation.
Rev.B
120 V Version
120 VAC
103.5
132 V
50
60 Hz
49.5
60.5 Hz
0.6 A
Approx. 20 W
(self-test with 10-cpi LQ characters)
minimum
10 M
(applying 500 VDC between
AC line and chassis)
1000 VAC rms - 1 minute or
1200 VAC rms - 1 second
(between AC line and chassis)
Operating
10
35 C (50
20
80% RH
1G (within 1 msec.)
0.15 G
Humidity
(% RH)
8 0 %
5 5 %
2 0 %
10˚ C
(50˚ F)
Figure 1-6. Temperature/Humidity Range
220 - 240 V Version
(self-test with 10-cpi LQ characters)
(applying 500 VDC between
AC line and chassis)
1500 VAC rms - 1 minute
(between AC line and chassis)
*1
95 F)
20
*1,3
Guaranteed range
˚ C
27˚ C
35˚ C
(80˚ F)
(95˚ F)
(˚ F)
Product Description
220 - 240 VAC
198
264 V
50
60 Hz
49.5
60.5 Hz
0.4 A
Approx. 20 W
10 M , minimum
Non Operating
*2
60 C ( 4
122 F)
*2,3
5
85% RH
*2
2G (within 2 msec.)
2
0.50 G
1-7