EPSON Stylus Color 980

1.2.6 Electrical Specifications

[120V version]
Rated voltage:
AC120V
Input voltage range:
AC99 132V
Rated frequency range: 50
Input frequency range: 49.5
Rated current:
0.7A (Maximum 1.0A)
Power consumption:
Approx.30W (ISO/IEC 10561 Letter pattern)
Energy Star compliant
Insulation Resistance: 10 M ohms min.
(between AC line and chassis, DC 500 V)
Dielectric strength:
AC1000 V rms. 1 minute or AC1200 Vrms.
1 second (between AC line and chassis)
[220 240V version]
Rated voltage:
AC220V
Input voltage range:
AC198
Rated frequency range: 50
Input frequency range: 49.5
Rated current:
0.4A (Maximum 0.5A)
Power consumption:
Approx.30W (ISO/IEC 10561 Letter pattern)
Energy Star compliant
Insulation Resistance: 10M ohms min.
(between AC line and chassis, DC500V)
Dielectric strength:
AC1500 V rms.
1 minute (between AC line and chassis)
Product Description
60 Hz
60.5 Hz
240V
264V
60Hz
60.5Hz

1.2.7 Environmental Condition

Temperature:
Humidity:
Figure 1-7. Temperature / Humidity of Range
Resistance to shock:
Resistance to vibration: Operating = 0.15G (Operating)
*1: With a shipment container
*2: Without condensation
Specifications
Revision A
Operating = 10 to 35 C (See Figure 1-7.)
Non-operating = -20 to 60 C *1
1 month at 40 C
120 hours at 60 C
Operating = 20% ~ 80% RH *1
(See Figure 1-7.)
Non-operating = 5% ~ 85% RH *1 *2
Operating = 1G, within 1 ms
Non-operating = 2G, within 2 ms *1
Non-operating = 0.50G *1
17