5.4 Throat plate removal
3
2
1
Caution: danger of injury!
Turn off the main switch.
Remove and mount throat plate only when the sewing unit is switched off.
Throat plate removal
–
Unscrew screw 1.
–
Pull lever 2 away from the knife mechanism 3.
–
Unscrew screw 3.
–
Remove throat plate.
Mount throat plate.
–
Put on throat plate.
–
Screw throat plate tight with screws 3.
–
Place lever 2 onto the bolts of the knife mechanism 3.
–
Insert screw 1 and tighten.
3
3
31