DFX-8500
Beta No.
BETA 3'
BETA 2
BETA 3
BETA 4
*1: When EEPROM is reset.
4-14
Figure 4-19. Thickness Gauge Setting Method
Table 4-1. BETA Values Adjustment
Reference Thickness Gauge
0.43 mm with 150gf pull
0.00 mm
0.43 mm
0.80 mm
Allowed Value Default Value*1)
-
367 - 419
405 - 437
418 - 475
-
408
435
461
Rev. B