ADJUSTMENTS & OPTIONAL SETTINGS (CONT.)
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
NOTE: Access to the remaining functions in LEVEL 2 is intended for trained service personnel only.
More in depth information can be found in the Axiom Service Manual 39132.0000

SET PASSWORD

0
0

SET LANGUAGE

NO
UNITS
METRIC DONE
SET TEMP:
(-)
DONE
SET READY:
(-)
DONE
ENTER ASSET # ?
NO
Any 3 digit number may be programmed to prevent unauthor-
ized access of LEVEL 2. BE CAREFUL TO USE A CODE YOU WILL
0
REMEMBER!
Choose between English or Spanish. After selecting "YES",
press either ( + ) or ( - ) to select, then choose "YES" again
YES
when asked, "ARE YOU SURE?"
Choose between English or Metric units. Display will read:
"CHANGING UNITS WILL CAUSE" "ALL SETUP INFO TO BE
ENG
LOST" "ARE YOU SURE?" "NO
is set for Metric Units, displays will be different. (ex: Brew oz
will become Brew Liters, ° F will be ° C).
Adjusts brew tank temperature.
200°
RANGE: (185 to 205° F) or (85 to 96° C)
(+)
This function sets the minimum temperature allowable to start
195°
a brew cycle. Range: (2° to 20° F) or (2° to 10° C) below the set
(+)
temperature. The water must be at the "READY" temperature
or higher for the display to indicate "READY TO BREW".
This function allows the you to enter in an optional asset num-
ber. This can be useful for tracking the usage or service of an
YES
individual machine within a group.
Page 9
YES". NOTE: If the brewer
41154 041708