ADJUSTMENTS & OPTIONAL SETTINGS (CONT.)
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
SET PULSE BREW ?
NO
DRIP TIME 0:30
(-)
DONE
ENABLE CLEAN
NO
DONE
Enabl EnergySavr
NO
DONE YES
EnableFreshTimer
NO
DONE YES
ENABL WARMER OFF
NO
DONE
0
REFILL
(-)
DONE
This function allows the sprayhead to "pulse" on and off dur-
ing a brew cycle. These times can be set two different ways.
YES
The fi rst is by setting the total brew time in the "EASY PULSE
BREW" screen. The other option allows the actual times to be
entered in the "MANUAL PULSE BREW" screen.
NOTE: This will overwrite settings in "BREW METER".
Adjusts the DRIP TIME (time from end of sprayhead fl ow to
when liquid stops dripping from the funnel). When the brew
(+)
cycle is complete, the display will show "DRIPPING" and will
countdown the time until the funnel empties.
RANGE: "OFF" or 0:05 to 4:00 minutes
Set the time before a cleaning alert will be displayed.
RANGE: 1 to 30 days
YES
Enables the mode function and sets the idle time. Then choose
to have the tank heater(s) turn off, or reduce the tank temp to
(140° F) or (60° C) once the set idle time has expired.
Range: 0.5 to 24.0 hrs
Enables the "FRESHNESS ALERT!" message and sets the
expiration time. The expiration time is the amount of time the
product is allowed to sit in the server before an alert message
is displayed.
Range: 0.5 to 4.0 hrs
Sets the amount of time a warmer will remain on after being
turned on. Each warmer has an independent timer and is af-
YES
fected by its corresponding switch. NOTE: The lower "Brew"
warmer timer is restarted when brew switch is pressed. Range:
15mins to 6.0 hrs in 15 min increments.
Adjusts the sensitivity of the refi ll circuit. Water in different
155
geographical locations can have different conductivities. Make
(+)
sure the water in the tank is touching the refi ll probe. NOTE:
Always make sure that the # on the right is larger than the #
on the left when water is contacting the tank refi ll probe.
Page 10
"EASY PULSE BREW" times:
Min: Base brew time + 40 seconds
Max: Base brew time + 3:00 minutes
41154 041708