Using the [RS232C] port

By connecting the [RS232C] port of the unit to
the RS-232C port of your computer, you can con-
trol the unit from the computer.
For controlling the unit via RS232C remotely, set
the "Remote Sel." menu item in the REMOTE SET
menu of the MENU mode to "All" or "Remote", as
described in the previous page. Also set the baud
rate using the "RS232C Setup" menu item in the
REMOTE SET menu if required.
The table below shows the pin assignment of the
[RS232C] port.
Pin No.
1
2
3
4
5
6
7
8
9
<Specifications>
• Cable: Male-female, straight cable
• Baud rate: Selectable from 9600, 19200, 38400,
57600 and 115200 (default) bps
• Data bit: 8 bits
• Parity bit: Non
• Stop bit: 1 bit
5
1
9
6
Signal
IN/OUT
NC
OUT
TX
RX
IN
NC
GND
NC
NC
NC
NC
Model UR-2 <Controlling from an external device>

Setting "RS232C Setup" menu

You can set the baud rate of the control signal
using the "RS232C Setup" menu item.
In the following procedure, it is assumed that the
display shows the main menu screen of the RE-
MOTE SET menu, on which the "Remote Sel."
menu item is set to "All".
(1)
Use the [MENU] dial to highlight "RS232C
Setup" and press the [ENTER] key.
The display shows the RS232C setup screen.
On this screen, you can only select the baud
rate. The other items are display-only.
(2)
While the baud rate value is highlighted, press
the [ENTER] key.
The current setting ("115200" by default)
starts flashing and you can now select a baud
rate from the following.
9600, 19200, 38400, 57600, and 115200 (de-
fault) bps
(3)
Use the [MENU] dial to select the desired baud
rate and press the [ENTER] key to confirm the
selection.
(4)
Press the [STOP] key to exit the MENU mode.
-63-