Bryant DuraPac 558F Installation & Service Instructions Manual page 11

Single package rooftop electric heat/electric cooling unit
Hide thumbs Also See for DuraPac 558F:
Table of Contents

Advertisement

VOLTAGE
NOMINAL
RANGE
UNIT
VOLTAGE
558F
(3 Ph, 60 Hz)
Min
Max RLA LRA RLA LRA RLA LRA Qty Hp
208/230
187
253
180
460
414
508
208/230
187
253
210
460
414
508
208/230
187
253
240
460
414
508
Table 2 — Electrical Data
COMPRESSOR
No. 1
No. 1A
No. 2
32.1
195
20.7
156
16.4
95
10
30.1
225
28.8
195
15.5
114
14.7
42
239
33.6
225
19.2
125
17.3
114
OFM
IFM
FLA
Hp
FLA
(ea)
3
0.5
1.7
5.0
15.8/15.8
70
3
0.5
0.8
5.0
7.9
3
0.5
1.7
5.0
15.8/15.8
95
3
0.5
0.8
5.0
7.9
2
1
6.6
7.5
25.0/25.0
2
1
3.3
7.5
13.0
11
POWER
ELECTRIC
EXHAUST
HEAT*
FLA LRA
kW
FLA
4.6
18.8
26/34
71/ 82
109/122
4.6
18.8
26/34
71/ 82
114/128
42/56
117/135
166/155
4.6
18.8
42/56
117/135
172/161
56/75**
156/180
176/200
4.6
18.8
56/75**
156/180
182/206
2.3
6.0
39
32
2.3
6.0
32
39
55
66
2.3
6.0
55
66
80**
96
2.3
6.0
80**
96
4.6
18.8
26/34
71/ 82
109/122
4.6
18.8
26/34
71/ 82
114/128
42/56
117/135
166/155
4.6
18.8
42/56
117/135
172/161
56/75
156/180
176/200
4.6
18.8
56/75
156/180
182/206
2.3
6.0
32
39
2.3
6.0
32
39
55
66
2.3
6.0
55
66
80
96
2.3
6.0
80
96
124/124
4.6
18.8
129/129
26/34
71/ 82
124/134
4.6
18.8
26/34
71/ 82
129/140
42/56
117/135
178/166
4.6
18.8
42/56
117/135
183/172
56/75
156/180
187/211
4.6
18.8
56/75
156/180
193/217
2.3
6
32
39
2.3
6
32
39
55
66
2.3
6
55
66
80
96
2.3
6
80
96
Table continued on next page.
POWER SUPPLY
MCA
MOCP†
82/ 82
110/110
86/ 86
110/110
110/125
125/150
175/175
175/175
200/225
200/225
41
50
43
50
59
60
62
70
76
90
79
90
106
125
109
125
87/ 87
110/110
92/ 92
110/110
110/125
125/150
175/175
175/175
200/225
200/225
44
50
47
60
59
60
61
70
76
90
79
90
106
125
109
125
150/150
150/150
150/150
150/150
200/175
200/175
200/225
200/225
61
80
63
80
65
80
68
80
82
90
85
90
112
125
115
125

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Durapac series

Table of Contents