System Console Selection; The Du Command Screen - HP rp7440 Installation Manual

Installation guide, fourth edition - hp integrity rx7640 and hp 9000 rp7440 servers
Hide thumbs Also See for rp7440:
Table of Contents

Advertisement

After logging in to the MP, verify that the MP detects the presence of all the cells installed in the
cabinet. It is important for the MP to detect the cell boards. If it does not, the partitions will not
boot.
To determine if the MP detects the cell boards:
1.
At the MP prompt, enter cm.
This displays the Command Menu. The Command Menu enables viewing or modifying the
configuration and viewing the utilities controlled by the MP.
To view a list of the commands available, enter he. Press Enter to see more than one screen
of commands. Use the Page Up and Page Down keys to view the previous or next screen of
commands. To exit the Help Menu, enter q.
2.
From the command prompt (MP:CM>), enter du.
The du command displays the MP bus topology. A screen similar to the following is
displayed:
Figure 2-35 The du Command Screen
There will be an asterisk (*) in the column marked MP.
3.
Verify that there is an asterisk (*) for each of the cells installed in the cabinet, by comparing
what is in the Cells column with the cells physically located inside the cabinet.
Figure 2-35
physically located in slots 0 and 1.

System Console Selection

Each operating system requires that the correct console type be selected from the firmware
selection menu. The following section describes how to determine the correct console device.
If an operating system is being installed or the system configuration is being changed the system
console setting must be checked to ensure it matches the hardware and OS. Not checking the
console selection can result in the system using an unexpected device as a console, which can
appear as a system hang when booting.
1.
Determine the console you want to use.
Depending on your operating system and your hardware you can select one of two possible
devices as your system console. The possibilities are:
Management Processor (MP) Serial Port
VGA device
shows that cells are installed in slots 0 and 1. In the cabinet, cells should be
Cabling and Power Up
67