50 amp automatic transfer switch

Advertisement

Available languages

Available languages

Installation

Unpacking

Delivery Inspection
After removing the carton, carefully inspect the transfer
switch components for any damage that may have occurred
during shipment.
IMPORTANT: If loss or damage is noted at time of delivery,
have the person(s) making delivery note all damage on the
freight bill and affix his signature under the consignor's
memo of loss or damage. If loss or damage is noted after
delivery, contact the carrier for claim procedures. Missing or
damaged parts are not warranted.
Shipment Contents
• Automatic Power Transfer Switch
• Installation and Operator's Manual
240V
To Water Heater
To Briggs & Stratton
Home Generator Unit
120V To Microwave
120 V To Bathroom
240V To Well Pump
120V To Sump Pump
6
To Utility Power
To Range
Neutral

Essential Circuit Isolation

Essential electrical loads are loads that will be powered by
the Home Generator System. Essential loads are grouped
together and wired into the transfer switch.
TO THE INSTALLER: Consult with Home Generator System
owner(s) to discuss their "Selection of Essential Circuits",
described in the operator's manual.
Ensure that the total of the selected load circuits fed by this
transfer switch are within the generator's rated capacity.
The following requirements apply to this type of isolation
system:
• The Automatic Transfer Switch is installed after the
main distribution panel.
• The Automatic Transfer Switch has a load rating of
50 Amps. This is the maximum load rating of the
essential loads.
All wiring must conform to national, state and local codes.
The illustration below depicts the Home Generator System
and assumes the utility is supplying 120/240 Volt, single-
phase electrical service.
Watt Meter
Main Distribution Panel
To Air Conditioner (240V)
To Other Circuits (120V)
Automatic Transfer Switch
(in normal position)
120V To Freezer
To Refrigerator
To Lights
To Furnace Blower
120V
BRIGGSandSTRATTON.COM