Battery Charging And Maintenance - PSC PowerScan RF System Manual

Hide thumbs Also See for PowerScan RF:
Table of Contents

Advertisement

Battery Charging and Maintenance

12
LED and Beeper Indications
Maximizing Signal Range
Three-Position Lock
When the scanner is in use, a low battery condition
is indicated by a repeated two-flash signal from the
scanner's green LED every time the trigger is pulled
before the laser is enabled. This indicator may have
been disabled via custom programming. See LED
NOTE
and Beeper Indications for more information.
Seat the scanner in the Base Station as shown in Figure 6, ensuring that
the battery fully engages the station's metal contacts. The CHARGE
LED on the Base Station should flash, indicating the battery is charg-
ing.
Figure 6. Charging the Battery
Rapid flashing indicates that charging is taking place. Rapid charging
occurs when the battery temperature is between 10°C (50°F) and 46°C
(115°F), and/or voltage of the battery is between 2.0 and 3.2V. Charge
time is less than 4.2 hours. Rapid charge ends with the battery at
approximately 90 to 95% capacity. The CHARGE LED remains on
steady when trickle charging or after the charge cycle is complete.
A scanner may be charged simultaneously while
other scanners are in use with the Base Station.
NOTE