Diagnostics panel

The following illustration shows the controls and LEDs on the diagnostics panel.
To access the diagnostics panel, slide the release latch on the front of the operator
information panel to the left.
The following table lists the LEDs on the diagnostics panel and suggested actions
to solve the detected problems.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Hardware Maintenance Manual to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
LED
Description
None, but
An error has occurred and cannot be
the
diagnosed, or the Advanced System
system-
Management (ASM) processor on the
error LED
Remote Supervisor Adapter II SlimLine
is lit.
has failed. The error is not represented
by a diagnostics LED.
OVER
The power supplies are using more
SPEC
power than their maximum rating.
PS 1
The power supply in bay 1 has failed.
26
ThinkServer RD120 Types 6444, 6445, 6446, and 6447: User Guide
Light Path
Diagnostics
OVER SPEC
CPU
REMIND
MEM
SP
FAN
PCI
PS1
PS2
VRM
CNFG
NMI
S ERR
DASD
RAID
TEMP
BRD
Action
Check the system-error log for information about the error.
1. Remove optional devices from the server.
2. Replace the failing power supply.
Attention:
In a dc power environment, only trained
service personnel other than Lenovo service technicians are
authorized to connect or disconnect power to the dc power
supply and to remove and install a dc power supply. See
the documentation that comes with each dc power supply.
Attention:
In a dc power environment, only trained service
personnel other than Lenovo service technicians are authorized
to connect or disconnect power to the dc power supply and to
remove and install a dc power supply. See the documentation
that comes with each dc power supply.
1. Make sure that the power supply is correctly seated.
2. Replace the failed power supply.