Installing the microprocessor air baffle

To install the microprocessor air baffle, complete the following steps:
1. Read the safety information that begins on page v and "Installation guidelines"
2. Make sure that the server and peripheral devices are turned off (see "Turning
3. Remove the cover (see "Removing the cover" on page 31).
4. Place your fingers into the two finger holes on the top of the air baffle.
5. Align the tab on the left side of the air baffle with the slot in the left side of the
6. Lower the air baffle into the server.
36
ThinkServer RD120 Types 6444, 6445, 6446, and 6447: User Guide
1
Microprocessor air baffle
2
Finger holes
on page 29.
off the server" on page 12) and that all power cords and external cables are
disconnected.
Attention:
In a dc power environment, only trained service personnel other
than Lenovo service technicians are authorized to connect or disconnect power
to the dc power supply. See the documentation that comes with each dc power
supply.
chassis.
Attention:
For proper cooling and airflow, replace the air baffle before you
turn on the server. Operating the server with an air baffle removed might
damage server components.