Fluke 116 User Manual page 21

True-rms multimeter
Table of Contents

Advertisement

IP Rating (dust and water protection)
Function
DC millivolts
DC Volts
[1]
Auto-V LoZ
True-rms
[1]
AC millivolts
True-
rms
[1]
C Volts
True-rms
A
............
IP42
Table 1. Accuracy Specifications
Range
600.0 mV
0.1 mV
6.000 V
0.001 V
60.00 V
0.01 V
600.0 V
0.1 V
600.0 V
0.1 V
600.0 mV
0.1 mV
6.000 V
0.001 V
60.00 V
0.01 V
600.0 V
0.1 V
Resolution
DC, 45 to 500 Hz
2.0 % + 3
45 to 500 Hz
1.0 % + 3
1.0 % + 3
True-rms Multimeter
General Specifications
Accuracy
([% of Reading] + [Counts])
0.5 % + 2
0.5 % + 2
500 Hz to 1 kHz
4.0 % + 3
500 Hz to 1 kHz
2.0 % + 3
2.0 % + 3
19

Advertisement

Table of Contents
loading

Table of Contents