Dell PowerVault NX3100 Hardware Owner's Manual page 35

Powervault nx3100 systems
Hide thumbs Also See for PowerVault NX3100:
Table of Contents

Advertisement

Message
Timer chip
counter 2 failed.
TPM
configuration
operation
honored. System
will now reset.
TPM
configuration
operation is
pending. Press
(I) to Ignore
OR (M) to Modify
to allow this
change and reset
the system.
WARNING:
Modifying could
prevent
security.
TPM failure.
Unable to launch
System Services
image. System
halted!
Causes
Faulty system board.
A TPM configuration
command has been entered.
The system reboots and
executes the command.
This message displays during
system restart after a TPM
configuration command has
been entered. User
interaction is required to
proceed.
A Trusted Platform Module
(TPM) function has failed.
System halted after <F10>
keystroke because System
Services image is either
corrupted in the system
firmware or has been lost due
to system board replacement.
The optional iDRAC6
Enterprise card flash memory
or BMC SPI flash may be
corrupted.
Corrective Actions
See "Getting Help" on
page 157.
Information only.
Enter I or M to proceed.
See "Getting Help" on
page 157.
Restart the system and
update the Lifecycle
Controller repository to the
latest software to restore full
functionality. See the
Lifecycle Controller User
Guide for more information.
Restore the flash memory
using the latest version on
support.dell.com. See the
Integrated Dell™ Remote
Access Controller 6
(iDRAC6) User Guide for
instructions on performing a
field replacement of the
flash memory.
About Your System
35

Hide quick links:

Advertisement

Table of Contents
loading