Dell PowerVault NX3100 Hardware Owner's Manual page 31

Powervault nx3100 systems
Hide thumbs Also See for PowerVault NX3100:
Table of Contents

Advertisement

Message
No boot device
available.
No boot sector on
hard drive.
No timer tick
interrupt.
PCIe Training
Error: Expected
Link Width is x ,
Actual Link Width
is y .
Causes
Faulty or missing optical
drive subsystem, hard drive,
or hard drive subsystem, or
no bootable USB key
installed.
Incorrect configuration
settings in System Setup
program, or no operating
system on hard drive.
Faulty system board.
Faulty or improperly
installed PCIe card in the
specified slot.
Corrective Actions
Use a bootable USB key,
optical drive, or hard drive.
If the problem persists, see
"Troubleshooting a USB
Device" on page 130,
"Troubleshooting an Internal
USB Key" on page 139, and
"Troubleshooting a Hard
Drive" on page 140.
See "Using the System Setup
Program and
UEFI Boot Manager" on
page 41 for information on
setting the order of boot
devices.
Check the hard drive
configuration settings in the
System Setup program.
See "Using the System Setup
Program and
UEFI Boot Manager" on
page 41. If necessary, install
the operating system on your
hard drive. See your
operating system
documentation.
See "Getting Help" on
page 157.
Reseat the PCIe card in the
specified slot number.
See "Troubleshooting
Expansion Cards" on
page 143. If the problem
persists, see "Getting Help"
on page 157.
About Your System
31

Hide quick links:

Advertisement

Table of Contents
loading